Introduction
Always consult your local Building Department regarding regulations, 
codes or ordinances which apply to the installation of a direct vent wall 
furnace.
Instructions to Installer
1.  Installer  must  leave  instruction  manual  with  owner  after 
installation.
2.  Installer must have owner fill out and mail warranty card supplied 
with furnace.
3.  Installer should show owner how to start and operate furnace and 
thermostat.
Warning:
Any change to this furnace or its control can be dangerous. This 
is a heating appliance and any panel, door or guard removed for 
servicing an appliance must be replaced prior to operating the 
appliance.
General Information
This furnace is design certified in accordance with American National 
Standard/CSA Standard Z21.86 and CSA 2.32 by the Canadian Standards 
Association, as a fan type direct vent wall furnace to be installed according 
to these instructions.
Any alteration of the original design, installed other than as shown in 
these instructions or use with a type of gas not shown on the rating plate 
is the responsibility of the person and company making the change.
Important
All correspondence should refer to complete Model No., Serial No. and 
type of gas.
Notice: During initial firing of this unit, its paint will bake out and smoke 
will occur. To prevent triggering of smoke alarms, ventilate the room in 
which the unit is installed.
Installation on Rugs and Tile
If this appliance is installed directly on carpeting, tile or other combustible 
material other than wood flooring the appliance shall be installed on a metal 
or wood panel extending the full width and depth of the appliance. 
The base referred to above does not mean the fire-proof base as used on 
wood stoves. The protection is for rugs that are extremely thick and light 
colored tile.
Installation in Residential Garages
Gas utilization equipment in residential garages shall be installed so that 
all burners and burner ignition devices are located not less than 18” above 
the floor.
Such equipment shall be located, or protected, so it is not subject to physical 
damage by a moving vehicle. 
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment or 
accessories  and  repair  and  servicing  of  equipment  shall  be  performed 
only  by  a  qualified  agency.  The  term  “qualified  agency”  means  any 
individual, firm, corporation or company which either in person or through 
a representative is engaged in and is responsible for (a) the installation 
or replacement of gas piping or (b) the connection, installation, repair or 
servicing of equipment, who is experienced in such work, familiar with 
all precautions required and has complied with all the requirements of the 
authority having jurisdiction.
State of Massachusetts: The installation must be made by a licensed 
plumber or gas fitter in the Commonwealth of Massachusetts.
The installation must conform with local codes or, in the absence of local 
codes, with the National Fuel Gas Code ANSI Z223.1/NFPA 54* Natural 
Gas and Propane Installation Code, CSA B149.1.
*Available from the American National Standards Institute, Inc., 11 West 
42nd St., New York, N.Y. 10036.
High Altitudes
For altitudes/elevations above 2,000 feet, input ratings should be reduced 
at the rate of 4 percent for each 1,000 feet above sea level. For Canadian 
high  altitude  applications,  this  appliance  is  suitable  for  installation  at 
elevations between 0 feet and 4,500 feet  without change.
Piezo Pilot Ignitor Instructions
Depressing the red button completely causes a spark to occur at the pilot. This 
is a substitute for a match which requires opening the pilot hole cover.
To  light  the  pilot,  it  is  important  that  the  electrode  be  1/8”    from  the 
thermocouple. The spark must occur at the point the burner flame hits the 
thermocouple. The end of the electrode will be red hot with the pilot on.
On a new installation with air in the gas line, it is suggested that a match 
be used. The match will light the pilot faster than the piezo under this 
condition. 
Model
DVC-35T
DVC-35IPT
Input BTU/HR
35,000
35,000
Height
72 1/2”
72 1/2”
Width
14 1/8”
14 1/8”
Depth
10 3/8”
10 3/8”
Gas Inlet
1/2” Pipe
1/2” Pipe
CFM
275
275
Accessories
SOR-1
Register, Side Outlet
SOK-1
Side Outlet Kit, 10” (25.4cm) Boot Assembly with Register
*DV-822
Vinyl Siding Vent Kit
*  DV-822, Vinyl siding vent kit, adds 3” to wall depth. You must include the three (3) additional inches for TOTAL wall depth when ordering a 
vent kit.