Empire Comfort Systems DV-35-2SG Manuale Utente

Pagina di 20
12434-9-0107
Page 10
Warning:  When vinyl  siding vent kit, DV-822 or 2" x 4"  
(51mm x 102mm) framing is added to an existing installation 
(furnace is installed) do not attempt to add sections of pipe to 
the flue outlet tube or air inlet tube.  An air tight seal is required 
for both tubes.  Refer to Parts List, page 14 to order tubes.
 
Millivolt wall thermostats are specially designed for use on self-
generating systems.  They should never be used on line or low 
voltage A.C. circuits.
Interior Wall — The thermostat should be installed on an inside 
wall away from the furnace but in the same room.  
It is important to use wire of a gauge proper for the length of the 
wire:
RECOMMENDED WIRE GAUGES
 
Maximum Length 
Wire Gauge
 
1' to 10' 
18
 
10' to 25' 
16
 
25' to 35' 
14
Proper operation depends on a good pilot flame.  The flame must 
cover the top of the thermopile.  Cleaning of the pilot orifice and 
burner may be required due to spiders.
System Check (Figure 6)
A millivolt meter is required to check the system.  Millivolt readings 
should be:
•  Across  the  thermopile  terminals,  400-450  millivolts  with  
thermostat OFF.
•  Across  the  thermopile  terminals,  150-250  millivolts  with  
thermostat ON.
•  Across the thermostat wires at the valve, less than 30 millivolts 
with  thermostat ON.
•  Across the thermostat wires at the thermostat, less than 5 millivolts 
with thermostat ON.  (Strong winds, dirty pilot and low pressure 
will reduce readings.)
Piezo Pilot Ignitor Instructions
Depressing the red button completely causes a spark to occur at 
the pilot.  This is a substitute for a match which requires opening 
the pilot hole cover.
To light the pilot, it is important that the electrode be  1/8" (3mm) 
from the thermopile.  The spark must occur at the point the burner 
flame hits the thermopile.  The end of the electrode will be red hot 
with the pilot on.
On a new installation with air in the gas line, it is suggested that a 
match be used. The match will light the pilot faster than the piezo 
under this condition.
Figure 5a
Figure 5
Figure 6
THERMOSTAT LOCATION