Empire Comfort Systems DV-35-2SG Manuale Utente

Pagina di 20
12434-9-0107
Page 9
On solid wall, when using wall studs for attachment of wall mounting 
bracket, fasten wall mounting bracket to wall studs with (2) #10 x 
1 1/2" (38mm) screws provided and fasten  (2) additional #10 x 1 
1/2" (38mm) screws provided through the wall mounting bracket 
and into the solid wall. 
On sheet rock, when using wall studs for attachment of wall mounting 
bracket, fasten wall mounting bracket to wall studs with (2) #10 
x 1 1/2" (38mm) screws provided and by using wall opening for 
access, fasten 2 additional #10 x 1 1/2" (38mm) screws and (2) 
Tinnerman nuts provided through the wall mounting bracket and 
into the sheet rock.
Attaching Furnace To Wall Mounting Bracket  
Hang furnace on wall mounting bracket by aligning (2) tabs on wall 
mounting bracket with (2) slots located on inner casing top.
The inner casing bottom is to be fastened to the wall.  On solid wall, 
fasten inner casing bottom with (2) #10 x 1 1/2" (38mm) screws 
provided.  On sheet rock wall, fasten inner casing bottom with (2) 
toggle bolts provided.
Cutting Vent Tubes
This is the most important part of the installation.  With the furnace 
installed on wall the 6" (152mm) diameter air inlet tube and the 4" 
(102mm) diameter flue outlet tube are to be marked and cut using 
the following procedure.
1.  Attach 6" (152mm) diameter air inlet tube onto the collar of air 
drop assembly.  Be sure 6" (152mm) diameter air inlet tube is 
placed as far as possible onto the collar of the air  drop assembly.  
Mark the 6" (152mm) diameter air inlet tube 1/2" (13mm) beyond 
the outside wall.  Remove 6" (152mm) diameter air inlet tube 
from collar of air drop assembly.
2.  Attach 4" (102mm) diameter flue outlet tube onto flue outlet 
collar on combustion chamber.  Be sure 4" (102mm) diameter 
flue outlet tube is placed as far as possible onto the collar of 
flue outlet.  Mark the 4" (102mm) diameter flue outlet tube 2 
1/2" (64mm) beyond the outside wall.  Remove 4" (102mm) 
diameter flue outlet tube from collar of flue outlet on combustion 
chamber.
3.  Mark or wrap tape completely around the tubes at the marked 
points to help in making a true cut.  Do not crimp or enlarge 
tubes.
Installing Vent Assembly
1.  Place provided caulking beneath the edge of the outside mounting 
plate.  Use additional caulking to correct uneven wall surface, 
such as clapboard.
2.  Attach 6" (152mm) diameter air inlet tube onto the collar of 
air drop assembly.  Attach caulked, outside mounting plate into 
the 6" (152mm) diameter air inlet tube.  Position the outside 
mounting  plate  so  that  6"  (152mm)  diameter  air  inlet  tube 
has a slight downward slope to the outside.  The downward 
slope is necessary to prevent the entry of rainwater.  Attach 
outside mounting plate to exterior wall with (4) #10 x 1 1/2" 
(38mm)screws provided.
3.  Apply furnace cement to 4" (102mm) diameter flue outlet collar 
on combustion chamber and to 4" (102mm) diameter  collar on 
vent cap.  Attach 4" (102mm) diameter flue outlet tube onto flue 
outlet collar on combustion chamber.  Attach vent cap into the 
4"(102mm) diameter flue outlet tube.  Attach vent cap to outside 
mounting plate with (3) #10 x 1/2" (13mm) screws provided.
4.  Installation is completed.
Reassembly And Resealing Vent-Air Intake System
When vent-air intake system is removed for servicing the furnace, 
the following steps will assure proper reassembly and resealing of 
the vent-air intake assembly.
1.  Remove old furnace cement from flue outlet collar on combustion 
chamber and collar of vent cap.  Remove old furnace cement 
from both ends of 4" (102mm) diameter flue outlet tube.
2.  Remove old caulking beneath the edge of the outside mounting 
plate.   Apply  new  caulking  beneath  the  edge  of  the  outside 
mounting plate.  Use additional caulking to correct uneven wall 
surface, such as clapboard.
3.  Attach  6" (152mm) diameter air inlet tube onto the collar of 
air drop assembly.  Attach caulked, outside mounting plate into 
the 6" (152mm) diameter air inlet tube.  Position the outside 
mounting plate so that 6" (152mm) diameter air inlet tube has 
a slight downward slope to the outside.  The downward slope 
is necessary to prevent the entry of rainwater.  Attach outside 
mounting plate to exterior wall with (4) #10 x 1 1/2" (38mm) 
screws provided.
4.  Apply furnace cement to 4" (102mm) diameter flue outlet collar 
on combustion chamber and to 4" (102mm) diameter  collar on 
vent cap.  Attach 4" (102mm) diameter flue outlet tube onto flue 
outlet collar on combustion chamber.  Attach vent cap into the 4" 
(102mm) diameter flue outlet tube.  Attach vent cap to outside 
mounting plate with (3) #10 x 1/2" (13mm) screws provided.
5.  Reassembly  and  resealing  vent-air  intake  system  is 
completed.
Installing a Vent Near a Window Ledge, Other Type of Projection 
or on Siding (vinyl, aluminum, etc.)
Direct  vent  furnaces  are  designed  to  be  installed  on  a  uniform 
outside wall.  When the wind comes from any angle (up, down  or 
from either side), it must hit the vent cap equally over both the air 
inlet and the flue outlet portions of the vent.  Any wall projection, 
such as a door or window casing, which disturbs the wind on one 
side of the air inlet section will result in back pressure on the flue 
section smothering the flame and eventual pilot outage.
When the vent cap is to be installed on siding or it appears that a 
projection within 6" (152mm) of any side of the air inlet section 
could shield the air inlet section, the entire vent should be supported 
away from the wall at least the distance of the projection. 2" x 
4" (51mm x 102mm) framing whose outside dimensions match 
the  overall  dimensions  of  the  mounting  plate  is  recommended.   
The 2" x 4" (51mm x 102mm) framing protects siding from possible 
warpage or discoloration.  All joints can then be sealed and painted. 
The wall depth plus the additional depth of the 2" x 4" (51mm x 
102mm) framing should not exceed a total depth of 13" (330mm) 
for DV-25 and DV-35.  (See Figure 5)
Vinyl siding vent kit, DV-822,  is available from Empire Comfort 
Systems, Inc.  The depth is 3" (76mm), which enables the vent cap 
to be extended away from siding or projections.  The wall depth 
plus the additional 3" (76mm) depth of the vinyl siding vent cap 
extension should not exceed a total depth of 13" (330mm) for DV-
25 and DV-35. (See Figure 5a)
INSTALLATION INSTRUTIONS (continued)