Your garage door opener is programmed with 
self-diagnostic capabilities. The “Learn” button/diagnostic LED will 
flash a number of times then pause signifying it has found a 
potential issue. Consult Diagnostic Chart below.
Diagnostic Chart
Symptom: One or both of the Indicator lights on the safety sensors do not 
glow steady.
•  Inspect sensor wires for a short (staple in wire), correct wiring polarity (black/white 
wires reversed), broken or disconnected wires, replace/attach as needed.
• Disconnect all wires from back of motor unit.
•  Remove sensors from brackets and shorten sensor wires to 1-2 ft. (30-60 cm) 
from back each of sensor.
•  Reattach sending eye to motor unit using shortened wires. If sending eye indicator 
light glows steadily, attach the receiving eye. 
•  Align sensors, if the indicator lights glow replace the wires for the sensors. If the 
sensor indicator lights do not light, replace the safety sensors.
Symptom: LED is not lit on door control.
•  Inspect door control/wires for a short (staple in wire), replace as needed.
•  Disconnect wires at door control, touch wires together. If motor unit activates, 
replace door control.
•  If motor unit does not activate, disconnect door control wires from motor unit. 
Momentarily short across red and white terminals with jumper wire. If motor unit 
activates, replace door control wires.
Symptom: Sending indicator light glows steadily, receiving indicator light is 
dim or flashing.
• Realign receiving eye sensor, clean lens and secure brackets. 
• Verify door track is firmly secured to wall and does not move.
Symptom: Motor has over heated; the motor unit does not operate or trolley is 
stuck on stop bolt = Motor unit hums briefly; RPM Sensor = 
Short travel 6-8" (15-20 cm). 
• Unplug unit to reset. Try to operate motor unit, check diagnostic code.
•  If it is still flashing 5 times and motor unit moves 6-8" (15-20 cm), replace 
RPM sensor. 
•  If motor unit doesn’t operate, motor unit is overheated. Wait 30 minutes and retry. 
If motor unit still will not operate replace logic board.
Symptom: Motor unit doesn’t operate.
• Replace logic board because motor rarely fails.
Motor Circuit Failure.
Replace Receiver 
Logic Board.
Motor overheated or 
possible RPM sensor 
failure. Unplug to reset.
Safety reversing sensors
slightly misaligned
(dim or flashing LED).
Door control or 
wire shorted. 
Safety reversing sensors 
wire shorted or black/
white wire reversed.
Safety reversing sensors 
wire open (broken or 
disconnected). 
1 FLASH
2 FLASHES
3 FLASHES
4 FLASHES
5 FLASHES
6 FLASHES
OR