REMINGTON QFP40 Direct Vent FIREPLACE
250-4721   JUNE 2001
1 - 1/2" Long
Wood Screws
Ceiling Joists
Framing
Step 4. Assemble the desired lengths of GS pipe and elbows necessary to reach from
the  stove  up  through  the  round  support  box.  Ensure  that  all  pipe  and  elbow
connections are in their fully twist-locked position. Be sure to seal the outer pipe
with appropriate sealant (high temperature silicone).
Step 5. Cut a hole in the roof centered on the small drill hole placed in the roof in Step 2.
The  hole  should  be  of  sufficient  size  to  meet  the  minimum  requirements  for
clearance to combustibles, as specified.  Continue to assemble lengths of pipe
and elbows necessary to reach from the ceiling support box up through the roof
line. Galvanized pipe and elbows may be utilized in the attic, as well as above
the roofline. The galvanized finish is desirable above the roofline, due to its higher
corrosion  resistance.
NOTE:
(1)
 If an offset is necessary in the attic to avoid obstructions, it is important to sup-
port the vent pipe every 3' (914mm) to avoid excessive stress on the elbows, and
possible separation.  Wall straps are available for this purpose (page 38, Figure
11).
(2)
Whenever possible, use 45° elbows, instead of 90° elbows. The 45° elbow of-
fers less restriction to the flow of flue gases and intake air.
Step 6. Slip the flashing over the pipe section(s) protruding through the roof. Secure the
base  of  the  flashing  to  the  roof  with  roofing  nails.  Insure  the  roofing  material
overlaps  the  top  edge  of  the    flashing  as  shown  in  Figure  14.  Verify  that  the
chimney is the required height above the roof.  See “2-10-3 Vertical Termination
Rule” on page 28 of this manual
Step 3. To install the round support box/wall thimble in a flat ceiling, cut a 10" (254mm)
square hole in the ceiling, centered on the hole drilled in Step 2. Frame the hole
as shown in Figure 13.
SHINGLES OVERLAP
TOP EDGE OF
FLASHING
VENTING
FIG. 13
FIG. 14
VERTICAL INSTALLATION INSTRUCTIONS