NOTE:  Termination  cap  should  pass  through  the  wall  firestop 
from the exterior of the building. Adjust the termination 
cap to its final exterior position on the building.
WARNING: Termination cap must be positioned so that arrow 
is pointing up.
Attach the termination cap with the four wood screws provided. 
Before attachment of the termination, run a bead of silicone sealant 
rated above 250°F on its outside edge too, so as to make a seal to 
the exterior wall.
NOTE Wood screws can and should be replaced with appropriate 
fasteners for use on stucco, brick, concrete or other types 
of siding.
CAUTION:  If  exterior  walls  are  finished  with  vinyl  siding  (or 
materials that could become discolored or warp), it is necessary 
to install a vinyl siding standoff.
The  vinyl  siding  standoff  will  be  installed  between  the  vent 
termination and the exterior wall. (See Figure 43) This horizontal vent 
termination bolts onto the flat portion of the vinyl siding standoff, so 
an air space will exist between the wall and the termination cap.
Figure 43
For installations requiring a vertical rise on the exterior of the 
building,  14-inch  and  36-inch  tall  Snorkel  Terminations,  as 
shown in Figure 44 are available. Follow the same installation 
procedures as used for standard Horizontal Terminations. If the 
Snorkel Termination must be installed below grade, (i.e. basement 
application), proper drainage must be provided to prevent water 
from entering the Snorkel Termination. Refer to Figure 45. Do not 
attempt to enclose the Snorkel within the wall or any other type 
of enclosure.
12 INCHES
MINIMUM
SNORKEL
12 INCHES
MINIMUM
ADEQUATE
DRAINAGE
SNORKEL
Figure 44
Figure 45
HORIZONTAL TERMINATION