IMPORTANT: Read through the emitter replacement 
procedure below before beginning the replacement.
CAUTION: Do not touch emitter with bare hands. 
Wearing soft cotton gloves is highly recommended.
1. Turn OFF power switch and disconnect from main 
power supply (circuit breaker). 
2. Be sure the heater and emitter are cool: burns can 
result from touching hot components.
3. Remove the screws from the end of the heater 
fixture and remove the aluminum end cap.
4. Carefully slide the perforated front grille immedi-
ately adjacent to the end cap off the end of the unit.
5. Carefully slide the protective grille to the end of 
the heater to expose the emitter and silicone seal-
ing connectors.
6. Carefully remove the emitter and silicone wire 
connectors from the aluminum emitter clips, free-
ing the wire/connector system.
7. Carefully remove the silicone terminal connec-
tors from the ends of the emitter. Be careful not to 
break the emitter terminal end inside the silicone 
wire connector. Discard the used emitter.
8. Holding the new emitter by the ceramic ends OR 
wearing clean dry gloves, place the silicone termi-
nal connectors onto the new emitter and re-clip it 
into the emitter holder.
9. Carefully slide the protective grille and perforated 
end cap into place, and replace screws.
MAINTENANCE
There are only two maintenance procedures which 
can be done on location: cleaning the unit and 
replacing the emitter. Return the heater to an au-
thorized service faciity for any other electrical or 
mechanical adjustment or repair, including replace-
ment of a damaged power cord.
Should the heater be dropped or damaged, or mal-
function at any time, immediately turn off the main 
power source and do not use heater until it has been 
examined by an authorized service facility.
CLEANING
To remove dust or dirt on the reflector, follow these 
steps:
1. Turn the power switch OFF and disconnect heater 
from the main power supply.
2.  Remove the wire guard and carefully wipe the 
reflector with a soft, lint-free cloth.
CAUTION: Do not touch the emitter. Finger marks 
will burn into the quartz emitter during use and 
cause premature heater failture.
If emitter is inadvertently touched, or if it needs to be 
cleaned, carefully wipe it using rubbing alcohol or 
methylated spirits.
REPLACING EMITTER
Contact your distributor for the correct replacement 
emitter, providing the model number and rating from 
the rating label. Not using an exact replacement 
emiitter can cause the heater to fail.
Installation & Operation 
Radiant Infrared Heater 
Heat Controller
:HOOZRUWK$YH-DFNVRQ0,‡3K‡ZZZKHDWFRQWUROOHUFRP
Due to ongoing product improvements, specifications and dimensions 
are subject to change and correction without notice and without 
incurring  obligations.  Determining  the  application  and  suitability 
for use of any product is the responsibility of the installer. Addition-
ally, the installer is responsible for verifying dimensional data on 
the actual product prior to beginning any installation preparations.
Incentive and rebate programs have precise requirements as to 
product performance and certification. All products meet applica-
ble regulations in effect on date of manufacture; however, certifi-
cations are not necessarily granted for the life of a product. There-
fore, it is the responsibility of the applicant to determine whether a 
specific model qualifies for these incentive/rebate programs.
4