WIRING INSTRUCTIoNS FoR INSTALLING A DUAL SWITCH / RECEPTACLE
In order to install both the optional Blower and Accent Light ac-
cessories, it will be necessary to install the junction box so that 
the Duplex Receptacle wiring is split. This will allow each side of 
the receptacle to operate independently off separate wall switches. 
See diagram below.
CAUTION: ALL WIRINg ShOULD BE DONE By A qUAL-
IfIED ELECTRICIAN AND ShALL BE IN COMpLIANCE 
WITh ALL LOCAL, CITy AND STATE BUILDINg CODES. 
BEFoRE  MAKING  THE  ELECTRICAL  CoNNECTIoN, 
MAKE SURE THAT MAIN PoWER SUPPLY IS DISCoN-
NECTED. ThE AppLIANCE, WhEN INSTALLED, MUST 
BE  ELECTRICALLy  gROUNDED  IN  ACCORDANCE 
WITh LOCAL CODES OR, IN ThE ABSENCE Of LOCAL 
CODES,  WITh  ThE  NATIONAL  ELECTRICAL  CODE 
ANSI/NFPA 70 (LATEST EDITIoN).
#1
ACCENT LIGHT
WALL SWITCH
#2
BLOWER
WALL
SWITCH
REMOVE TAB ON HOT SIDE
OF DUPLEX RECEPTACLE
TO SPLIT LUGS
PLUG
FOR
CONTROLS
PLUG
FOR
BLOWER
FIREPLACE
CONTROL
COMPARTMENT
DUAL SWITCH ELECTRICAL WIRING TO FIREPLACE RECEPTACLE
RED
BLACK
WHITE
3-WIRE, GROUNDED
CONDUCTOR
(BY OTHERS)
DOUBLE SWITCH BOX
(INSTALLER PROVIDED)
BLACK
WHITE
GROUND
TO 120V
CIRCUIT
BREAKER
1.  To wire Junction Box Receptacle, remove the tab on the side 
of the receptacle (hot side) to split receptacle. This will be 
required to separate blower and Accent Light circuits.
2.  Power for switched and live sides of Duplex Receptacle must 
come from the same power source. (One circuit breaker on 
main panel must switch all power off.)
3.  From the wall box to the fireplace a 3-wire conductor with 
ground is recommended, however (2) two-wire conductors 
with grounds may be used in place of a 3-wire conductor with 
a ground if the black wires from the Accent Light and blower 
accessories are identified.
4.  Two wall switches may be used to activate the two receptacle 
plugs independently.
Note: Wiring to the Junction Box should be run through the 7/8" 
diameter access hole located on one of the sides of the fireplace 
outer wall. A Romex type connector is provided and should be 
used to protect and restrain the wiring where it passes through 
the fireplace outer wall. The Junction Box should be positioned in 
the lower compartment of the fireplace/firebox so that it does not 
interfere with moving parts of the blower assembly. The Junction 
Box incorporates magnets on the bottom side to retain and reduce 
the chance of movement or vibration during blower operation.
Note: If only the blower option is to be installed, wiring may be 
performed as described and illustrated in the following Blower 
Installation section.