Desa CGMFP Manuale Utente

Pagina di 36
www.desatech.com
119315-01A
16
iNsTallaTioN
Continued
PRESSURE TESTING FIREPLACE GAS 
CONNECTIONS
1.  Open equipment shutoff valve (see Figure 16, 
page 15).
2.  Open main gas valve located on or near gas 
meter for natural gas or open propane/LP 
supply tank valve.
3.  Make sure control knob of fireplace is in the 
OFF position.
4.  Check all joints from equipment shutoff valve 
to gas regulator (Manual-Controlled Models) 
or to gas control valve (Remote-Ready Mod-
els) (see Figures 17 or 18, page 15). Apply 
noncorrosive leak detection fluid to all joints. 
Bubbles forming show a leak.
5.  Correct all leaks at once.
6.  Light fireplace (see Operating Fireplace, page 
18). Check all other internal joints for leaks.
7.  Turn off fireplace (see To Turn Off Gas to Appli-
ance, page 20 for Manual-Controlled Models 
or page 21 for Remote-Ready Models).
OPTIONAL WIRELESS HAND-HELD 
REMOTE CONTROL ACCESSORIES
Remote-Ready Models Only
(HRC100 & HRC200 Series)
Installing Receiver
1.   Disconnect jumper wire from control valve 
(see Figure 19).
2.   Locate battery clip mounted on back of re-
ceiver (see Figure 20).
3.  Slide 9-volt battery (not included) through 
clip.
4.  Attach terminal wires to battery (see Figure 20). 
5.  Connect wires from remote receiver to control 
valve as shown in Figure 21.
6.  Install remote receiver unit onto remote bracket 
using screws provided (see Figure 21).
Figure 21 - Installing Remote Receiver
Remote 
Receiver
Figure 19 - Disconnecting Wires From 
Control Valve
Figure 20 - Attaching Battery to Receiver
Battery Clip
9-Volt 
Battery
Receiver
Terminal 
Wires
Control 
Valve
Jumper 
Wire
White Wire 
to TPTH 
Terminal on 
Control Valve
Red Wire to TH 
Terminal on Control 
Valve
Installing 9-Volt battery in Hand-Held 
Remote Control Unit
1.  Remove  battery  cover  on  back  of  remote 
control unit.
 2.  Attach  terminal  wires  to  the  battery  (not 
included).  Place  battery  into  the  battery 
housing.
3.   Replace battery cover onto remote control 
unit. 
Figure 22 - Installing Battery in Hand-
Held Remote Control Unit
9-Volt Battery
Battery 
Housing
Battery Cover
Terminal 
Wires
Remote Control Unit