SAFETY INFORMATION
Continued
PRODUCT IDENTIFICATION
Figure 1 - Direct-Vent Fireplace with Millivolt Ignition
LOCAL CODES
Install and use fireplace with care. Follow all local codes. In the 
absence to local codes, use the current National Fuel Gas Code  
ANSI Z223.1/NFPA 54* (USA) or the current CSA-B149.1 Instal-
lation Code (Canada).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
SAFETY INFORMATION
PRODUCT IDENTIFICATION
LOCAL CODES
Glass 
Door
Assembly
Switch Bracket for 
Optional Remote and 
Blower
Control
Valve with 
Piezo Ignitor
Log 
Set
Lava 
Rock
Upper Louver 
Panel
Lower 
Louver 
Panel
Flue Collar
Nailing
Flange
Burner 
Assembly
5.  This fireplace reaches high temperatures. Keep children and 
adults away from hot surfaces to avoid burns or clothing igni-
tion. Fireplace will remain hot for a time after shutdown. Allow 
surfaces to cool before touching.
6.  Carefully supervise young children when they are in the room 
with fireplace.
7.  Do not modify this fireplace under any circumstances. Any 
parts removed for servicing must be replaced prior to operating 
fireplace.
8.  Turn fireplace off and let cool before servicing, installing or 
repairing. Only a qualified service person should install, service 
or repair this fireplace. Have fireplace inspected annually by a 
qualified service person.
9.  You must keep control compartments, burners and circulating 
air passages clean. More frequent cleaning may be needed due 
to excessive lint and dust from carpeting, bedding material, etc. 
Turn off the gas valve and pilot light before cleaning fireplace.
10.  Have venting system inspected annually by a qualified service 
person. If needed, have venting system cleaned or repaired. See 
Cleaning and Maintenance, page 27.
11.  Keep the area around your fireplace clear of combustible ma-
terials, gasoline and other flammable vapor and liquids. Do 
not run fireplace where these are used or stored. Do not place 
items such as clothing or decorations on or around fireplace.
12.  Do not use this fireplace to cook food or burn paper or other 
objects.
13.  Do not use any solid fuels (wood, coal, paper, cardboard, etc.) 
in this fireplace. Use only the gas type indicated on fireplace 
nameplate.
14.  This appliance, when installed, must be electrically grounded 
in accordance with local codes or, in the absence of local 
codes, with the National Electrical Code, ANSI/NFPA 70 or 
the Canadian Electrical Code, CSA C22.1.
15.  Do not use fireplace if any part has been exposed to or under 
water. Immediately call a qualified service person to arrange 
for replacement of the unit.
16.  Do not operate fireplace if any log is broken. 
17.  Do not use a blower insert, heat exchanger insert or other ac-
cessory not approved for use with this fireplace.
18.  Do not operate fireplace with glass door removed, cracked or 
broken.
19.  Provide adequate clearances around air openings.
Glowing 
Embers
Andiron