5
5
www.desatech.com
116239-01B
A
B
E
F
G
H
D
C
Nailing Tabs
8
CLEARANCES
Minimum clearances to combustibles for the fireplace are as follows:
*Back and sides 
0"/mm
Perpendicular walls 
6" (152mm)
Floor 
0"/mm
Ceiling to louver opening  42" (1067mm)
Front 
36" (914mm)
Top of Standoffs 
0"/mm
Vent 
(See venting instructions for 
 
specific venting clearances.)
Combustible material with a maximum thickness of 5/8" may be 
flush with the top front of fireplace.
* For back and sides of fireplace, do not pack with insulation or 
other materials. Zero inch clearance to combustible materials are 
for framing purpose only.
NOTICE: This fireplace is intended for use as supple-
mental heat. Use this fireplace along with your primary 
heating system. Do not install this fireplace as your 
primary  heat  source.  If  you  have  a  central  heating 
system,  you  may  run  system’s  circulating  blower 
while using fireplace. This will help circulate the heat 
throughout the house. In the event of a power outage, 
you can use this fireplace as a heat source.
FRAMING AND FINISHING
Figure 4 shows typical framing of this fireplace. Figure 5 shows fram-
ing for corner installation. All minimum clearances must be met. 
PRE-INSTALLATION 
PREPARATION
Continued
 
Figure  4  -  Framing  Clearances  for  Installation  Against  an 
Exterior Wall
C
B
A
D
E
F
G
Top of Louver Opening
3
2
1
4
5
6
7
Wall
Figure 5 - Framing Clearances for Corner Installation
Ref.  Mantel Depth  Ref. 
Mantel from Top  
 
 
 
  of Louver Opening
  1  14" (356mm)   A 
  16" (406mm)
  2  12" (305mm)   B 
  14" (356mm)
  3  10" (254mm)   C    12" (305mm)
  4  8" (203mm) 
 D    10" (254mm)
  5  6" (152mm) 
 E 
  8" (203mm)
  6  4" (101mm) 
 F 
  6" (152mm)
  7  2" (51mm) 
 G    4" (101mm)
Figure 6 - Clearances for Combustible Mantels
PRE-INSTALLATION PREPARATION
Clearances
Framing and Finishing
40 
1
/
8
"
48 
1
/
4
"
25 
5
/
8
"
48"
48 
1
/
4
"
41 
5
/
8
"
21 
5
/
8
"
58 
1
/
2
"
16 
3
/
4
"
81 
1
/
2
"
13 
1
/
2
"
For available accessories for this fireplace, see Accessories on page 
36. If you are using a separate combustible mantel piece, refer to 
Figure 6 for proper installation height. You can install noncombus-
tible mantels at any height above the fireplace. 
Note: