Installation  of  an  outside  air  kit  should  be 
performed during rough framing of fireplace 
due to the nature of it's location. Outside com-
bustion air is accessed through a vented crawl 
space  (AK4F)  or  through  a  sidewall  (AK4). 
See Figure 24 on page 15 for instruction of 
operating air kit.
  CAUTION:  Combustion  air 
inlet  ducts  shall  not  terminate 
in attic space.
The  maximum  height  for  the 
air  vent  can  not  exceed  3  feet 
below the flue gas outlet of the 
termination.
VenTIng InsTallaTIon
CHIMNEY PIPE
DESA Heating, LLC chimney system consists 
of 12", 18", 24", 36" and 48" snap-lock, dou-
ble-wall pipe segments, planned for maximum 
adaptability  to  individual  site  requirements. 
Actual  lengths  gained  after  fitting  overlaps 
must  be  taken  into  consideration  (lineal 
gain) and are given in lineal gain chart (see 
Figure  8).  Lineal  gain  is  actual  measurable 
length of a part after two or more parts are 
connected. For Canada, use chimney parts 
designated "HT".
  WARNING:  The  opening  in 
collar around chimney at top of 
fireplace must not be obstructed. 
Never use blown insulation to fill 
chimney enclosure.
Hemmed 
End
8" Stainless 
Inner Pipe
12 
3
/
8
Galvanized 
Outer Pipe
LINEAL GAIN
PART NO.
DESCRIPTION
GAIN
36"
Fireplace
37 
1
/
2
"
12-8DM
12-8HT
Pipe Section
10 
5
/
8
"
18-8DM
18-8HT
Pipe Section
16 
5
/
8
"
24-8DM
24-8HT
Pipe Section
23 
5
/
8
"
36-8DM
36-8HT
Pipe Section
34 
5
/
8
"
48-8DM
48-8HT
Pipe Section
46 
5
/
8
"
RT-8DM
Round Termination
7
/
8
"*
RTL-8DM
Round Termination
3
/
4
"*
RTT-8DM
Round Termination 
with Slip Section
7
/
8
" to 
23 
1
/
8
"*
RTTL-8DM
Round Termination 
with Slip Section
1
/
2
" to  
21 
1
/
2
"*
ET-8DM
Square Chase-Top
12"*
ETO-8DM
Square Chase-Top 
with Mesh
12"*
ETL-8DM
Square Chase-Top 
with Slip Section
7" to 15"*
ETLO-8DM
Square Chase-Top 
with Mesh & Slip 
Section
12" to  
25 
1
/
2
"*
* The lineal gain for the terminations is 
measured to the flue gas outlet height.