York YOCC-YOHC 12-60 Manuale Utente

Pagina di 8
XT1
A B C
1
N
AB
C
N
12
3
XT2
XT1
4
Y&G
XT3
XT4
Y&G
Y&G
1234
A B C N 1
2 3
XT1
XT2
1
N
L
N 1 2(N)
XT1
XT3
LN
S
L N 1
3
2
1
N
L
N 1 2(N)
4
3
XT2
T3
E
XT1
T
 3 E
L(1)
N(1)
XT4
Y&G
123
4
5
6
Y&G
XT1
T3
E
XT2
L
N 1 2
3
XT2
T3
E
XT1
T
 3 E
L(1)
N(1)
XT4
Y&G
123
4
5
6
Y&G
XT1
T3
E
XT2
L
N 1 2
3
L
N
1
3
2
LN
1
3
2
XT3
XT1
XT2
XT1
T3 GND +5V
AB
C
N
Y&G
XT4
12
3
4
5
6
Y&G
A B C N 1
XT1
XT2
T3 GND +5V
2 3
(4)
5
XT2
XT1
T3 GND +5V
AB
C
N
Y&G
XT4
12
3
4
5
6
Y&G
A B C N 1
XT1
XT2
T3 GND +5V
2 3
(4)
5
3
1
2
L
N
3
1 2
L N
XT2
XT1
Y&G
Y&G
XT1
XT2
T3
E
T3
E
L
N
P
Q
(E)
Y/G
Y/G
L
N
X
Y
P
Q
(E)
Power supply
1-Phase
220-240V~ (3-core cable 3x2.5mm
2
)
Power supply
1-Phase
220-240V~ (3-core cable 3x1.0mm
2
)
3-core sheild cable
OUTDOOR UNIT
INDOOR UNIT
DC Inverter R-410A
For 18000-24000 Btu/h
3-core cable 3x2.5mm
2
3-core cable 3x2.5mm
2
OUTDOOR UNIT
INDOOR UNIT
POWER:
220-240V~50Hz
1-core sheild wire 1x0.5mm
2
3-core cable 3x2.0mm
2
5-core cable 3x2.5mm
2
5-core cable 3x2.5mm
2
OUTDOOR UNIT
INDOOR UNIT
POWER:
380V~50Hz
2-core sheild wire 1x0.5mm
2
4-core cable 3x2.0mm
2
5-core cable 3x2.5mm
2
5-core cable 3x2.5mm
2
OUTDOOR UNIT
INDOOR UNIT
POWER:
380V~50Hz
2-core sheild wire 1x0.5mm
2
4-core cable 3x2.0mm
2
1-core cable 1x2.0mm
2
1-core cable 1x2.5mm
2
Chart 30
30000~36000 Btu/h (1 PHASE)
Air Conditioner Link-circuit (For R-407C, Cooling & Heating)
3-core cable 3x2.5mm
2
3-core cable 3x2.5mm
2
OUTDOOR UNIT
INDOOR UNIT
POWER:
220-240V~50Hz
1-core sheild wire 1x0.5mm
2
3-core cable 3x2.0mm
2
3-core cable 3x2.5mm
2
3-core cable 3x2.5mm
2
OUTDOOR UNIT
INDOOR UNIT
POWER:
220-240V~50Hz
3-core cable 3x2.5mm
2
3-core cable 3x2.5mm
2
OUTDOOR UNIT
INDOOR UNIT
POWER:
220-240V~50Hz
1-core sheild wire 1x0.5mm
2
3-core cable 3x2.5mm
2
3-core cable 3x2.0mm
2
OUTDOOR UNIT
INDOOR UNIT
POWER:
220-240V~50Hz
Chart 27
24000~36000 Btu/h (1 PHASE)
Air Conditioner Link-circuit (For R-22, Cooling only)
3-core cable 3x2.5mm
2
3-core cable 3x2.5mm
2
OUTDOOR UNIT
INDOOR UNIT
POWER:
220-240V~50Hz
3-core cable 5x2.5mm
2
1-core cable 1x2.0mm
2
OUTDOOR UNIT
INDOOR UNIT
POWER:
380V 3N~50Hz
5-core cable 5x2.5mm
2
3-core cable 3x2.5mm
2
3-core cable 3x2.0mm
2
OUTDOOR UNIT
INDOOR UNIT
POWER:
220-240V~50Hz
5-core cable 5x2.5mm
2
3-core cable 3x1.5mm
2
OUTDOOR UNIT
INDOOR UNIT
POWER:
380V 3N~50Hz
5-core cable 5x2.5mm
2
12000 Btu/h (1 PHASE)
Air Conditioner Link-circuit (For R-410A and R-407C, Cooling
Only)
18000 Btu/h (1 PHASE)
Air Conditioner Link-circuit (For R-410A, Cooling Only)
36000~60000 Btu/h (3 PHASE)
Air Conditioner Link-circuit (For R-410A, R-407C and R-22,
Cooling & Heating)
Chart 23
Chart 22
24000 Btu/h (1 PHASE)
Air Conditioner Link-circuit (For R-410A, Cooling Only)
18000 Btu/h (1 PHASE)
Air Conditioner Link-circuit (For R-22, Cooling Only)
36000~60000 Btu/h (3 PHASE)
Air Conditioner Link-circuit (For R-410A, R-407C and R-22,
Cooling Only)
Chart 24
Chart 26
Chart 25
Chart 29
Chart 28
24000~36000 Btu/h (1 PHASE)
Air Conditioner Link-circuit (For R-407C, Cooling Only)
24000~36000 Btu/h (1 PHASE)
Air Conditioner Link-circuit (For R-22, Cooling & Heating)
Chart 32
Chart 31
24000~30000 Btu/h (3 PHASE)
Air Conditioner Link-circuit (For R-407C, Cooling & Heating)
24000~30000 Btu/h (3 PHASE)
Air Conditioner Link-circuit (For R-407C, Cooling only)