York R-410A ZH/ZJ/ZR Series Manuale Utente

Pagina di 206
528150-YTG-G-1210
56
Johnson Controls Unitary Products
115°F
125°F
1250
77
58.5
4.9
22.3
20.4
14.9
-
-
-
53.4
5.3
21.9
17.7
13.3
-
-
-
72
52.4
4.8
33.7
28.3
22.8
17.4
-
-
47.6
5.2
31.8
26.4
21.0
15.6
-
-
67
46.3
4.7
45.1
36.1
30.7
25.2
19.8
-
41.7
5.1
41.7
34.1
28.7
23.4
18.0
-
62
43.3
4.7
43.3
43.3
34.8
29.3
23.9
18.4
40.0
5.0
40.0
40.0
31.2
25.8
20.5
15.1
1500
77
60.5
4.9
29.6
23.1
16.7
-
-
-
55.1
5.3
29.6
21.3
14.9
-
-
-
72
54.2
4.9
38.3
31.9
25.5
19.0
-
-
49.1
5.3
36.3
29.9
23.6
17.2
-
-
67
47.9
4.8
47.1
40.7
34.3
27.8
21.4
-
43.0
5.2
43.0
38.6
32.2
25.8
19.5
-
62
44.8
4.7
44.8
44.8
38.9
32.4
26.0
19.6
41.2
5.1
41.2
41.2
35.0
28.6
22.3
15.9
57
43.1
4.7
43.1
43.1
38.5
32.1
25.7
19.2
39.7
5.1
39.7
39.7
35.4
29.0
22.6
16.3
1750
77
62.5
5.0
36.8
25.9
18.4
-
-
-
56.8
5.4
37.4
24.8
16.5
-
-
-
72
56.0
4.9
43.0
35.6
28.1
20.7
-
-
50.6
5.3
40.8
33.5
26.1
18.7
-
-
67
49.5
4.8
49.1
45.3
37.8
30.4
23.0
-
44.3
5.2
44.3
43.0
35.7
28.3
20.9
-
62
46.3
4.7
46.3
46.3
42.9
35.5
28.1
20.7
42.5
5.1
42.5
42.5
38.8
31.4
24.1
16.7
57
44.5
4.7
44.5
44.5
42.6
35.1
27.7
20.3
40.9
5.1
40.9
40.9
39.2
31.8
24.5
17.1
2000
77
64.5
5.0
44.1
28.6
20.2
-
-
-
58.5
5.5
45.1
28.4
18.1
-
-
-
72
57.8
5.0
47.6
39.2
30.8
22.4
-
-
52.1
5.4
45.4
37.0
28.6
20.3
-
-
67
51.1
4.9
51.1
49.8
41.4
33.0
24.6
-
45.6
5.3
45.6
45.6
39.2
30.8
22.4
-
62
47.8
4.8
47.8
47.8
47.0
38.6
30.2
21.8
43.8
5.2
43.8
43.8
42.6
34.2
25.9
17.5
57
45.9
4.8
45.9
45.9
46.6
38.2
29.8
21.4
42.2
5.2
42.2
42.2
42.2
34.7
26.3
17.9
2250
72
58.7
5.0
51.8
42.5
33.3
24.0
-
-
52.7
5.4
49.5
40.2
31.0
21.8
-
-
67
51.9
4.9
51.9
51.3
44.7
35.5
26.2
-
46.2
5.3
46.2
46.2
42.4
33.1
23.9
-
62
48.6
4.8
48.6
48.6
48.2
38.9
29.6
20.4
44.3
5.2
44.3
44.3
43.7
34.5
25.3
16.1
57
46.7
4.8
46.7
46.7
47.0
37.7
28.5
19.2
42.7
5.2
42.7
42.7
42.7
33.9
24.7
15.5
2500
72
59.6
5.0
55.9
45.8
35.7
25.6
-
-
53.4
5.4
53.4
43.4
33.4
23.3
-
-
67
52.7
4.9
52.7
52.7
48.0
37.9
27.7
-
46.8
5.3
46.8
46.8
45.6
35.5
25.4
-
62
49.3
4.8
49.3
49.3
49.3
39.2
29.1
19.0
44.9
5.2
44.9
44.9
44.9
34.8
24.7
14.6
57
47.4
4.8
47.4
47.4
47.4
37.3
27.1
17.0
43.3
5.2
43.3
43.3
43.3
33.2
23.1
13.0
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower 
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
ZJ061 (5.0 Ton) (Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F)
Return Dry Bulb (°F)
90
85
80
75
70
65
90
85
80
75
70
65