York R-410A ZH/ZJ/ZR Series Manuale Utente

Pagina di 206
528150-YTG-G-1210
58
Johnson Controls Unitary Products
115°F
125°F
1625
77
72.1
6.8
27.6
25.3
18.8
-
-
-
63.3
7.3
26.5
21.1
16.1
-
-
-
72
64.6
6.6
41.6
35.1
28.6
22.1
-
-
56.2
7.1
37.8
31.6
25.4
19.2
-
-
67
57.2
6.4
55.6
44.9
38.4
31.9
25.4
-
49.1
6.9
49.1
40.9
34.7
28.5
22.3
-
62
50.7
6.3
50.7
50.7
42.5
36.0
29.5
23.0
43.2
6.8
43.2
43.2
37.2
31.0
24.8
18.6
1950
77
75.3
6.8
36.7
28.9
21.1
-
-
-
66.8
7.4
36.3
25.9
18.4
-
-
-
72
67.5
6.6
47.7
39.9
32.1
24.3
-
-
59.3
7.2
44.1
36.5
29.0
21.4
-
-
67
59.8
6.5
58.7
50.9
43.1
35.3
27.5
-
51.8
7.0
51.8
47.1
39.6
32.1
24.5
-
62
53.0
6.4
53.0
53.0
47.8
40.0
32.2
24.4
45.6
6.8
45.6
45.6
42.5
34.9
27.4
19.8
57
56.6
6.4
56.6
56.6
49.6
41.8
34.0
26.2
52.3
6.9
52.3
52.3
43.4
35.9
28.4
20.8
2275
77
78.5
6.8
45.8
32.5
23.4
-
-
-
70.2
7.4
46.1
30.7
20.7
-
-
-
72
70.4
6.7
53.8
44.7
35.6
26.6
-
-
62.4
7.2
50.3
41.5
32.6
23.7
-
-
67
62.3
6.5
61.8
56.9
47.8
38.8
29.7
-
54.6
7.0
54.6
53.4
44.5
35.6
26.7
-
62
55.3
6.4
55.3
55.3
53.0
43.9
34.9
25.8
48.0
6.8
48.0
48.0
47.8
38.9
30.0
21.1
57
59.1
6.4
59.1
59.1
55.0
46.0
36.9
27.8
55.0
6.9
55.0
55.0
48.9
40.0
31.1
22.2
2600
77
81.7
6.9
54.9
36.1
25.7
-
-
-
73.7
7.5
56.0
35.5
23.0
-
-
-
72
73.3
6.7
59.9
49.5
39.2
28.8
-
-
65.5
7.2
56.6
46.4
36.2
25.9
-
-
67
64.9
6.6
64.9
62.9
52.6
42.2
31.9
-
57.3
7.0
57.3
57.3
49.4
39.1
28.9
-
62
57.5
6.4
57.5
57.5
58.3
47.9
37.5
27.2
50.4
6.9
50.4
50.4
50.4
42.8
32.6
22.3
57
61.5
6.5
61.5
61.5
60.5
50.1
39.7
29.4
57.6
7.0
57.6
57.6
54.3
44.1
33.8
23.6
2925
72
74.5
6.7
63.6
52.5
41.4
30.3
-
-
66.4
7.3
59.9
49.0
38.1
27.2
-
-
67
65.9
6.6
65.9
65.0
55.6
44.5
33.4
-
58.0
7.1
58.0
58.0
52.0
41.1
30.2
-
62
58.5
6.5
58.5
58.5
58.8
47.7
36.6
25.5
51.1
6.9
51.1
51.1
51.1
41.5
30.6
19.6
57
62.5
6.5
62.5
62.5
62.0
50.9
39.8
28.7
58.4
7.0
58.4
58.4
56.8
45.8
34.9
24.0
3250
72
75.7
6.8
67.3
55.4
43.6
31.8
-
-
67.2
7.3
63.2
51.6
40.0
28.4
-
-
67
67.0
6.6
67.0
67.0
58.5
46.7
34.9
-
58.8
7.1
58.8
58.8
54.7
43.1
31.5
-
62
59.4
6.5
59.4
59.4
59.4
47.6
35.8
23.9
51.7
7.0
51.7
51.7
51.7
40.1
28.5
16.9
57
63.5
6.5
63.5
63.5
63.5
51.7
39.8
28.0
59.2
7.1
59.2
59.2
59.2
47.6
36.0
24.4
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower 
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
ZJ078 (6.5 Ton) (Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F)
Return Dry Bulb (°F)
90
85
80
75
70
65
90
85
80
75
70
65