Raypak 182-400 Dépliant

Pagina di 2
Catalog No.:  2000.205D 
Effective:  1-1-08 
Replaces:  4-1-05
 
Job: 
 
           
 
Engineer: 
 
           
 
Contractor: 
 
           
 
Prepared By: 
            
 Date:
              
 
Model:  
           
 
Indoor 
   
EFFICIENT 
 82% efficiency – highest of any atmospheric boiler 
available today 
THERMAL SHOCK PROOF 
 Twenty-year warranty against thermal shock damage 
up to 150°F differential 
 Maximum operating temperature: 230°F 
LIGHTWEIGHT 
 A floor load of 70 lbs./sq. ft. or less 
HIGH RECOVERY 
 Cuts fuel costs substantially because the standby and 
radiation losses normal to other boilers and 
tank-type water heaters are eliminated 
LOW WATER OPERATING TEMPERATURE 
 Operates with water temperature as low as 
105°F without condensing 
 
Heat Exchanger 
ƒ  ASME Inspected and Stamped 
160 PSIG 
ƒ  National Board Approved 
ƒ Headers 
 Cast Iron Glass-lined – Standard 
 Bronze – Option A-1 
ƒ Finned 
Tubing 
 Copper – Standard 
 Cupro Nickel – Option A-3 
ƒ  ASME Steel Tube Sheet 
ƒ Silicone 
O-Rings 
ƒ  ASME Pressure Relief Valve 
 45 PSIG – Standard 
            PSIG ASME – Optional  
ƒ  Temperature and Pressure Gauge,  
Shipped Loose 
ƒ Water 
Connections 
 Left Hand – Standard 
 Right Hand – Option A-6 
ƒ  Flow Configuration – Two-pass 
ƒ  Pump – Optional 
 Mounted, 1/8 HP120 Volt, 1
∅, 60 Hz 
Controls 
ƒ  120V, 60Hz, 1 Ph Power Supply 
ƒ 120/24V 
Transformer 
ƒ  100% Pilot Shut-off/Lockout 
ƒ Electronic, 
Intermittent Ignition (IID) Pilot 
ƒ  High Limit Control, Manual Reset 
ƒ On/Off 
Switch 
ƒ Flow 
Switch 
ƒ  Economaster II Pump Time Delay 
Gas Control Train 
ƒ  Manual Main Gas Shut-off Cock 
ƒ  Main Gas Pressure Regulator 
ƒ  Redundant Safety Shut-off Valve 
ƒ  Control Valve         
ƒ Firing 
Mode 
 On/Off (H4) 
 Two-stage Firing (H3) 
 Mechanical Modulation, 
110-170°F (H5) 
 Mechanical Modulation,  
150-210°F (H1)  
ƒ Fuel 
 Natural Gas 
 Propane Gas 
ƒ  Design Certified ANSI Z21.13 
Construction 
ƒ Front 
Controls 
ƒ  Stainless Steel Burners 
ƒ  Polytuf Powder Coat Finish 
ƒ Vent 
Selection 
 Draft Diverter – Option D-10  
 Power Vent, Loose – Option D-2 
ƒ Base 
(Optional) 
 Combustible Floor Shield –  
Option J-1 
 
 
Temperature Controls 
Note:  H1 and H5 do not require a 
controller 
 B-6 
Two-stage – 100-200ºF  
 Y-241 Electronic Sequencer,  
1-4 Stages 
 
 Y-281 Electronic Sequencer,  
1-8 Stages
 
Additional Safety Controls 
 F-10  Low Water Cut-off Probe 
 I-1 
High Limit Control, Auto 
Reset, 240°F 
 S-1 
Low Gas Pressure Switch, 
Manual 
 S-2 
High Gas Pressure Switch, 
Manual 
                       
 
                       
 
Regulatory Agency Requirements 
            
 
            
 
 
 
 
 
 
 
 
Raytherm
®
 
- Type H
Hydronic Heating Boilers
Models 182-400 - Indoor