Regency F39-NG Manuale Utente

Pagina di 31
Regency
®
 F39 Room Sealed Freestanding Gas Stove
11
INSTALLATION
when cut will seat onto both the starter 
collar and the 90
o
 elbow.  Crimped 
section of rigid pipe seats into the 
90
o
 elbow. Only cut the uncrimped 
side of pipe. 
 
Dismantle all pipe sections including fl ue 
terminal.
3)  Attach the 4" dia. fl ex liner to the fl ue terminal 
ensuring that the fl ex overlaps the collar of 
the fl ue terminal by a minimum of 
 
1-3/8"(35mm). Use Mill-Pac to seal and 
secure with 3 of the #8 x 1/2" screws (stain-
less steel). 
 
4)  Attach the 2 ft. pipe section to the fl ue termi-
nal using Mill-Pac and/or high temperature 
silicone and attach with 3 of the #8 x 1/2" 
screws (stainless steel).
6)  A bead of non-hardening mastic should be 
run around both the termination and vinyl 
siding standoff to prevent water from entering 
and to make a tight seal between the cap 
and the standoff.
7)  Stretch the 4" dia. fl ex liner out fully and get 
a trial fi t of the liner onto the 4" dia. starter 
collar.
8)  Cut the 4" dia. fl ex liner to the desired 
size. 
 
Hint: leave an extra 12" to 16" of length, this 
will make the fi nal assembly easier to work 
with.
9)  Secure the 4" dia. fl ex liner to the 4" adapter 
with Mill-Pac and 3 of the #8 x 1/2" screws 
(stainless steel). 
10) Slide the Decorative Wall Cover over the 
pipe sections.
11) Slide the 90
o
 elbow (crimp end up) and the 
2 ft.  pipe section (crimp end up) over the 
4" dia. fl ex liner.
12) Slide the trim collar over the pipe section to 
cover the joint.
13) Install the spring spacers onto the pipe sec-
tions.
14) Secure the 4" dia. fl ex liner with adapter 
onto the stove collar. Put a bead of Mill-Pac 
around the appliance adapter and secure 
with 3 screws (#8 x 1/2, stainless steel).
15) Attach the pipe section onto the starter 
collar by sealing with Mill-Pac and/or high 
temperature silicone and securing with 3 of 
the #8 x 1/2" (black) screws. Pipe seams 
should be facing the wall.
16) Attach the 90
elbow onto the pipe section by 
sealing with Mill-Pac and/or high tempera-
ture silicone and securing with 3 of the #8 
x 1/2" screws (black).
17) Slide the 2 ft. pipe section onto the 90
o
 el-
bow. The fl ex may have to be compressed 
back in order for the pipe to properly mate 
to the elbow. Seal  with Mill-Pac and/or high 
temperature silicone and secure with 3 of 
the #8 x 1/2" screws (black). Pipe seams 
facing down.
18) Install the trim collar over the starter collar 
and secure with a #8 x 1/2" screw (black). 
If the pipe needs to be touched up, use only 
Stove Brite High Temperature Metallic Black 
Stove Paint.
NOTE: All inner joints must be sealed with 
Mill-Pac.
 
 
All outer joints may be sealed with 
high temperature silicone.
Note: The pipe seam should be facing 
down.
Note: To make the installa-
tion more aestheti-
cally pleasing, we 
recommend framing 
out a square that the 
cap can be mounted 
on.
Note:  If installing termination on a siding 
covered wall, a vinyl siding standoff 
or furring strips must be used to 
ensure that the termination is not 
recessed into the siding. For vinyl 
siding standoff installation refer to 
the Dura-Flue Termination instruc-
tions.
5)  Slide the partially connected pipe and fl ue 
terminal assembly through the wall (from 
the exterior into the interior) and secure the 
cap to the exterior wall with 4 of the supplied 
screws (#8 x 1-1/2" drill point, stainless 
steel).
Note:  The four screws provided for the 
fl ue cap should be replaced with ap-
propriate fasteners for stucco, brick, 
concrete, or other types of sidings.
 Hint: 
Apply 
the 
sealant (Mill-
Pac and/or high 
t e m p e r a t u r e 
silicone) to the 
outer pipe be-
fore connecting 
the inner pipe.
#8 x ½" (13mm) Self Tapping, Stainless Steel
#8 x ½"
Self Tapping, Black
(13mm)
#8 x 1½" (38mm) Drill Point, Stainless Steel