Regency F39-NG Manuale Utente

Pagina di 31
Regency
®
 F39 Room Sealed Freestanding Gas Stove
9
INSTALLATION
FLUING ARRANGEMENTS
Vertical Terminations Using 
Dura-Flue Fluing System for 
Residential Manufactured and Mobile Homes
The shaded area in the diagram below shows all allowable combi-
nations of straight vertical and offset to vertical runs with vertical 
terminations.
 Maximum two 45
o
 elbows.
If the fl ue is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" 
clearance to combustibles.
May be installed in Manufactured (Mobile) Homes after fi rst sale.
Horizontal Terminations for All Fluing Systems
The shaded areas in the diagram below show all allowable combina-
tions of vertical runs with horizontal terminations.  Maximum one 
90
O
 elbow (two  45
elbows equal one 90
o
 elbow).
LPG and NG: 
Residential, Manufactured and Mobile
Homes Installations
The fl uing arrangements diagrammed below, have a min. of 75% (fl ue 
loss) effi ciency with Fan Off, as required for manufactured homes. (Actual 
effi ciency may be as high as 85%)
May be installed in Manufactured (Mobile) Homes after fi rst sale.
Flue Restrictor Position
To set the Flue restriction as indicated in the diagram, simply loosen the 
screws and push the fl ue restrictor plate to the correct position. Tighten 
the screws.
Flue Restrictor setting at 
40 Mj/h 
Flue Restrictor setting at 
31 Mj/h