FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater
INSTALLATION
Diagram  2
HORIZONTAL  INSTALLATIONS
Diagram  1
*Dia 2:  Local codes or regulations may require
different  clearances.
RESIDENTIAL AND  MANUFACTURED  HOMES/
MOBILE  HOMES  INSTALLATIONS
You will require the following components with your new Regency Rear Flued Room Sealed Freestanding Gas Stove. Please review your product
to make sure you have everything you need. In the event that you are missing any part, contact your dealer.
Note: These  are  the  minimum  pieces  required.
Other  parts  may  be  required  for  your  particular  installation.
Minimum  components  for  a  Horizontal  Installation:
946-110
Horizontal Termination Kit which includes:
1
946-201
6-5/8" dia. x 18" (168mm dia. x 457mm) Black Pipe
1
946-207
4" dia. x 18" (102mm dia. x 457mm) Aluminum Flue
1
946-584
Astro Riser Vent Terminal
1
946-202
Wall Penetration Heat Shield for Heat Sensitive walls
(Wall Thimble) (2 pcs)
1
640-545
Decorative Wall Trim (Black)
1
948-128
Tube Mill-Pac
Screws
Optional  Components:
946-204
45
o
 Elbow - 6-5/8" (168mm) Black pipe
and 4" (102mm) Aluminum Flue
946-205
Vinyl Siding Shield for Riser Vent
Terminal
946-208/P
Flue Guard
940
Square Wall Thimble Cover*
942
Wall Penetration
Heat Shield*
* Simpson Dura-Vent  components
1) Set the unit in its desired location. Check to
determine if wall studs are in the way when
the fluing system is attached. If this is the
case, you may want to adjust the location
of the unit.
2) Assemble the desired combination of pipe
and  elbow  to  the  appliance  adapter  with
pipe seams oriented down. Offset the pipe
seams as double seams in one place will
cause the outer pipe to take an oval shape.
Kit comes complete with 18" (457mm) of
straight  flue  -  6-5/8"  (168mm)  dia.  black
outer pipe and 4" (102mm) dia. inner flue.
3) With the pipe attached to the stove, slide the
stove into its correct location, and mark the
wall  for  a 9-1/2" (241mm) (inside dimen-
sions) round hole. The center of the round
hole should line up with the centerline of the
horizontal pipe, as shown in diagram 1. Cut
and frame the 9-1/2 (241mm) round hole in
the  exterior  wall  where  the  flue  will  be
terminated. If the wall being penetrated is
constructed  of  non-combustible  material,
i.e. masonry block or concrete, a  7" (178mm)
diameter hole is acceptable.
Note:
a) The horizontal run of flue should have
a 1/4 inch (6mm) rise for every 1 foot
(305mm)  of  run  towards  the  termina-
tion. Never allow the flue to run down-
ward. This could cause high tempera-
tures and may present the possibility of
a fire.
b) The location of the horizontal flue termi-
nation on an exterior wall must meet all
local and national building codes, and
must not be blocked or obstructed. For
External  Flue Terminal Locations, see
diagram on page 7.
c) Snorkel  Terminations:
For installations requiring a vertical rise
on  the  exterior  of  the  building,  Astro
Riser  Vent  Terminations  as  shown  in
Dia.  2  is  available.  Follow  the  same
installation  procedures  as  used  for
standard Horizontal Termination.
NEVER install the Astro Riser vent up-
side  down.