SCHEDULED MAINTENANCE TABLE
(*): For the related procedure, see the Service Manual
(1): or before each start-up
(2): And after the first 8 running-in hours
(3): replace hydraulic oil for the first time after 500 hours, then after 2,000 hours or every year.
Maintenance operation
On delivery
Every 10 
hours
Every 50 
hours
Every 100 
hours
Every 200 
hours
Every 400 
hours
Battery fluid level check
(1)
Hopper lifting hydraulic system oil level check
(1)
Motor-to-main broom belt visual inspection and 
tension check
(*)
Skirt height and operation check
Side and main broom height check
Frame dust filter cleaning and integrity check
Closed pocket filter cleaning and integrity 
check
Filter-shaker operation check
(*)
Brake adjustment
 (*)
Nut and screw tightening check
(*) (2)
Drive wheel gearing chain tension check and 
cleaning
(*)
Steering chain cleaning
(*)
Vacuum hose integrity check
(*)
Pulley-to-main broom belt replacement
(*)
Motor-to-main broom pulley V-belt 
replacement
(*)
Hopper gasket integrity check
(*)
Hopper lifted position control microswitch 
adjustment check
(*)
Hopper horizontal position control micro-switch 
adjustment check
(*)
Motor carbon brush check and replacement
(*)
Hydraulic oil change
(*) (3)