therMostat settInGs - electronIc controls 
These models are equipped with an electronic control system. The 
control system senses temperature from a factory installed Immersion 
Temperature  Probe  (see  Figure  1). The  “Operating  Set  Point”  is 
adjusted to control water temperature. This is an adjustable user setting 
in the control system’s “Temperatures Menu.” This and all control 
system menus are accessed through the UIM (User Interface Module 
- see Figure 5) located on the front panel of the water heater.
The Operating Set Point is adjustable from 90°F/42°C to 190°F/88°C. 
The factory setting is 120°F/49°C. See the Electronic Control Models 
Operation section of this manual for instructions on how to adjust 
the Operating Set Point and other user settings.
uIM (user Interface Module)
fIGure 5
Set the Operating Set Point at the lowest setting which produces 
an acceptable hot water supply. This will always give the most 
energy efficient operation.
control systeM features
Advanced Diagnostics: Plain English text and animated icons display 
detailed operational and diagnostic information. LCD screen on the 
front of the water heater displays the Sequence of Operation in real 
time. Fault or Alert messages are displayed when operational problems 
occur. Advanced Service menu displays a list of possible causes for 
current Fault and Alert conditions to aid in servicing.
Economy Mode Operation: Control system automatically lowers 
the Operating Set Point by a programmed value during user defined 
time periods. Helps reduce operating costs during unoccupied or 
peak demand periods.
Linear Sequencing: Banks of heating elements (3 elements per 
bank) are energized according to adjustable (1 to 20°) differential 
set points for each bank. First bank on is the last bank off. Helps 
reduce operating costs during low/moderate loads.
control systeM naVIGatIon
The UIM (User Interface Module) is located on the front cabinet of the 
Electronic Control Model water heaters. All operational information 
and user settings are displayed and accessed using the UIM. The 
UIM includes five snap acting (momentary) user input buttons; an 
Up, Down and 3 Operational Buttons.
uIM - user Interface Module
fIGure 6.
up & down Buttons
Used to navigate (up and down) and to select (highlight) menu items. 
Also used to adjust or change (increase/decrease, on/off, set time) 
various user settings.
operational Buttons
The 3 Operational Buttons are multifunctional. Their current function is 
defined by the text that appears above each button on the LCD screen. 
The function will change depending on what menu is currently displayed 
or what menu item is selected. When no text appears on the LCD 
screen above an Operational Button there is no function assigned.
the desktop screen
Figure 7 below shows the control system “Desktop Screen.” This 
is the default screen. If there are no active Fault or Alert conditions 
and no user input for approximately 10 minutes the control system 
will return to this screen automatically.
Model Information
Model information and menu titles are shown in the black bar at the 
top of the Desktop Screen.
tank temperature
Current  water  temperature  as  sensed  from  the  immersion 
Temperature Probe.
Operating Set Point: Temperature at which the control system will 
maintain tank (water) temperature in the Normal Mode. This line of 
text will read 
economy set point whenever the control system is 
operating in the Economy Mode.
Status:  The  Operating  State  of  the  control  system  is  displayed 
beneath the Operating Set Point.
 
fIGure 7.
electronIc control Models operatIon