York 00497VIP Manuale Utente

Pagina di 112
YORK INTERNATIONAL
100
BIT PATTERNS TEST SCREEN
TROUBLESHOOTING
If any of the above tests do not perform correctly as 
described  above,  perform  the  applicable  procedure 
below:
Test Failed:
Bit  Patterns  -  If  the  vertical  bars  are  not  straight 
or  if  the  red  border  is  not  completely  visible,  either 
the Microboard Program Jumpers are not configured 
correctly or for the installed Display or the Microboard 
is defective.
All Red, All Green, All Blue, All White or All Black:
If  these  tests  do  not  produce  appropriate  solid  color 
screens, the Display Ribbon Cable, Display Interface 
Board, Microboard or Display could be defective. To 
locate  the  defective  component  perform  tests  in  the 
following order:
  1.  Display Ribbon Cable:
 
  Using  an  Ohmmeter,  perform  a  continuity 
test on all conductors in the ribbon cable. An 
open  circuit  would  indicate  the  ribbon  cable 
is defective.
  2.  Display Interface Board:
 
  Using an Ohmmeter, perform a continuity test 
on all conductors of the Interface Board. An 
open circuit would indicate the Interface Board 
is defective.
  3.  Microboard:
 
a. With the “All Red” test selected, the voltage 
at Microboard J5-6 through J5-11 (Red drivers 
bits  0-5),  as  measured  to  Gnd,  should  be  > 
3.0VDC. If not, the Microboard is defective.
 
b. With the “All Green” test selected, the voltage 
at  Microboard  J5-13  through  J5-18  (Green 
drivers bits 0-5), as measured to Gnd, should be 
>3.0VDC. If not, the Microboard is defective.
 
c. With the “All Blue” test selected, the voltage at 
Microboard J5-20 through J5-25 (Blue drivers 
bits  0-5),  as  measured  to  Grid,  should  be 
>3.0VDC. If not, the Microboard is defective.
 
d. With the “All White” test selected, the voltage at 
Microboard J5-6 through J5-11, J5-13 through 
J5-18  and  J5-20  through  J5-25  should  be 
>3.0VDC. If not, the Microboard is defective.
 
e. With  “All  Black”  selected,  the  voltage  at 
Microboard J5-6 through J5-11, J5-13 through 
J5-18  and  J5-20  through  J5-25  should  be 
<1.0VDC. If not, the Microboard is defective.
  4.  Display:
 
  If the Display Ribbon Cable, Display Interface 
Board and Microboard check OK per the above 
procedures, the Display is most likely the cause 
of the problem.
FIG. 51
00529VIPC
Service