CD-ROM Parameters Page
Inactivity Timer Multiplier
The inactivity timer multiplier specifies the length of time that the drive will remain
in the hold track state after completion of a SEEK or READ operation. The default
value is 0Dh. (i.e. 8 minutes). Table 2-6-14 gives a complete listing of the Inactivity
Timer Multiplier.
Number of S per M units
The number of S units per M unit field gives the ratio of these MSF address values.
For media conforming to the CD-ROM and CD-DA standard, this value is 60
(3Ch).
Number of F per S units
The number of F units per S unit field gives the ratio of these MSF address values.
For media conforming to the CD-ROM and CD-DA standard, this value is 75(4Bh).