Axor 10100801 Manuale Utente
09/2005
HANSGROHE PRODUCT SERVICE
Spare parts
LED-Display
LED off: normal operation
LED light: replacing battery
LED flashes every 2 s: water stop is activated
Technical data
Operation pressure: max. 117 psi
Recommended pressure: 14.7 - 72.5 psi
Test pressure: 232 psi
Hot water temperature: max. 176 ° F
Recommended hot water temperature: 149 ° F
Rate of flow: 1,7 gpm by 45 psi
Maximum flowing-out temperature at 122 ° F
temperature difference and 45 psi flow pressure:108 °F
Follow-on time: 1,5 s
Rise-delay time: 300 ms
Automatic switching-off: after 1 min
battery: 6 V / 1300 mAh Lithium
1 battery 97399000
2 connecting hose
3 battery box with cover 96317800
4 areator 94005800
5 fixation set 13961000
1
3
5
2
4