Technical Specifications
Recommended pressure 
45 - 72 psi
Maximum hot water temperature 
165° F*
Recommended hot water temp. 
120° - 140° F*
Nominal capacity @ 45 psi 
8 gpm
Nominal capacity @ 60 psi  
11.5 gpm
Safety stop 
100° F
Maximum output temperature 
110° F**
½” NPT connections
*Please know and follow all applicable local plumbing codes when setting the temperature on the water heater. 
**The high temperature limit stop may be reset to comply with local plumbing codes.  See page 11.
(For the sake of clarity, the plastic installation box 
(i-box) is not shown in these illustrations.  The 
i-box should not be removed.)
Rough-in 06627000 has service (isolation) 
stops built onto the valve.  When the screw-
driver slots is horizontal, the stops are in the 
“on” position.  When the screwdriver slots are 
vertical, the stops are in the “off” position.
When connecting the hot and cold supplies, 
hold the stop steady with a wrench to avoid 
stop mis-alignment, and breakage of the fac-
tory sealed thread compound.
The Service (Isolation) Stops
The cartridge shown is included 
with the trim kit.
screwdriver
slots