Flush the supply lines using the flushing plug
When finishing the wall, install the wall material up 
to the oval installation box.  
Do not remove the installation box.  
When the trim is installed, the plaster shield portion 
of the installation box will be trimmed nearly flush 
to the wall and sealed to provide protection against 
water damage.  
The installation box includes a flushing plug to 
permit line flushing and pressure testing before 
the cartridge and finishing parts are installed.  A 
pressure test of the installed piping should be per-
formed before the walls are closed.
The flushing plug permits cold water to flow from 
the bottom outlet and the hot water through the top 
outlet.   
To flush the lines, install a hose bibb and hose 
to each outlet line.  (Using a hose will permit the 
water to be directed to a location where it will 
not cause damage.)  Flush the lines for at least 5 
minutes. 
The porting in the flushing plug prevents cross flow.  
However, it does not stop the flow of water through 
the outlets.  