15.  Optional AD Converter Board 
The Optional AD Converter card for the TDA 2200 has input connectors for both balanced 
(XLR) and unbalanced (RCA) signals.  The input impedance of the inputs are 10 kOhm.
 
a.  Balanced inputs 
The balanced XLR inputs are wired in accordance with IEC268: 
Pin 1: Chassis and ground. 
Pin 2: Hot (+). 
Pin 3: Cold (-). 
Shell: Chassis and ground. 
b.  Unbalanced inputs 
The unbalanced RCA inputs are wired in accordance with normal practice: 
Shell: Chassis and ground. 
Pin: Hot (+). 
c.  Trigger connector 
The  TDA  2200  is  equipped  with  a  TRIGGER  OUT  3.5mm  mono  jack  connector.  The 
Trigger  signal  is  a  12V  short  circuit-protected  output  signal  for  powering  up  external 
equipment when the TDA 2200 is on, e.g. remotely connected SDA 2175 power amplifiers 
or active subwoofers. 
16.  Cleaning and Maintenance 
 
 
Always unplug the unit from the electrical outlet before cleaning. 
 
 
This  unit  does  not  require  any  regular  maintenance  except  to  keep  its  exterior  clean. 
Simply  wipe  its  exterior  with  a  clean  soft  cloth.  A  small  amount  of  non-abrasive  cleaner 
may be used on the cloth to remove any excessive dirt or fingerprints. Do not use abrasive 
cleaners or cleaners containing liquid solvents.