Lucent Technologies Release 7 Manuale Utente

Pagina di 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1124
M/T-PKT (Maintenance/Test Packet Bus Port) 
9
Table 9-447.
TEST #567 Consistency Test 
Error 
Code
Test 
Result
Description/ Recommendation
2000
ABORT
Response to the test request was not received within the allowable time 
period.
2100
ABORT
System resources necessary to run this test are not available.
2500
ABORT
An internal operation failed, and the test could not be completed.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
2059
FAIL
The M/T-PKT has reported a failure of the on-board self-test.
2060
FAIL
The M/T-PKT has reported an invalid state for the Packet Bus.
2061
FAIL
The SPE cannot communicate with the M/T-PKT, but is able to communicate 
with the Maintenance/Test Circuit Pack.
1. Retry the command.
2. If the test continues to fail, replace the Maintenance/Test circuit pack 
and retry the command.
3. If the test continues to fail, refer to PKT-BUS Maintenance 
documentation to determine if the M/T-PKT failure is being caused by a 
Packet Bus fault.
PASS
The M/T-PKT Packet Bus fault detection capability is operating correctly.
Continued on next page