Lucent Technologies Release 7 ユーザーズマニュアル
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1124
M/T-PKT (Maintenance/Test Packet Bus Port)
9
Table 9-447.
TEST #567 Consistency Test
Error
Code
Code
Test
Result
Description/ Recommendation
2000
ABORT
Response to the test request was not received within the allowable time
period.
period.
2100
ABORT
System resources necessary to run this test are not available.
2500
ABORT
An internal operation failed, and the test could not be completed.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
2059
FAIL
The M/T-PKT has reported a failure of the on-board self-test.
2060
FAIL
The M/T-PKT has reported an invalid state for the Packet Bus.
2061
FAIL
The SPE cannot communicate with the M/T-PKT, but is able to communicate
with the Maintenance/Test Circuit Pack.
with the Maintenance/Test Circuit Pack.
1. Retry the command.
2. If the test continues to fail, replace the Maintenance/Test circuit pack
and retry the command.
3. If the test continues to fail, refer to PKT-BUS Maintenance
documentation to determine if the M/T-PKT failure is being caused by a
Packet Bus fault.
Packet Bus fault.
PASS
The M/T-PKT Packet Bus fault detection capability is operating correctly.
Continued on next page