Petsafe RFA-200 Manuale Utente

Pagina di 64
1-800-732-2677 (US), 1-800-457-3911 (Canada)
Additional Boundary Wire
We recommend the use of 20 gauge insulated multi-strand copper 
wire for direct burial. Extra Boundary Wire can be purchased in 500 
foot spools at the store where you purchased the kit or through the 
Customer Care Center at 1-800-732-2677.
Note: When adding Boundary Wire, it must act as a continuous loop.
The table at right indicates the approximate length of Boundary Wire 
needed for a rectangular, Single Loop layout. Length will vary due to 
the amount of twisted wire and layout used.
Acres
Feet of Wire Needed
1/4
415
1/3
480
1/2
590
1
835
2
1180
5
1870
10
2800
__________________________________________________
Connect the Wires to the Fence Transmitter
Boundary Wire
 (4A)
1. Run the Boundary Wire to the Fence Transmitter through a window, under 
a door, through a crawl space vent, or any other appropriate available access. 
You can also drill a hole through your wall.
2. Strip the ends of the Boundary Wire approximately one-half inch.
3. Insert the Boundary Wires into the Boundary Wire Terminals on the Fence 
Transmitter.
4. Turn the Boundary Width Control knob to 10. This will set the Warning Zone 
at the maximum width. 
5. Plug the Power Adapter into the Power Jack and a 120-volt outlet.
6. The Power Light and Loop Indicator Lights should come on. If this does not 
happen, see the “Troubleshooting” section.
Lightning Protection (sold separately)
You may purchase a Lightning Protection Kit through the Customer Care
}
Boundary Width 
Control
Power Light
Loop Indicator 
Light
Boundary Wire 
Terminals
Power
Jack
4A
Center at 1-800-732-2677. The Lightning Protection Kit protects the system against surges that travel through the 
power source and/or the Boundary Wire. 
__________________________________________________
Prepare the Receiver Collar
Your Receiver Collar comes with short Contact Points installed. Use the long Contact Points for pets with long or 
thick hair. Tighten the Contact Points one-quarter to one-half turn beyond finger tight (5A). Check the tightness 
weekly. 
To Insert and Remove the Battery
Note: Do not install the battery while the Collar Receiver is on your pet.
1. Remove the screws with a Philips screwdriver.
2. Remove the Battery Lid (5B).
3. Install a 9-volt alkaline battery (5C).
4. Replace the Battery Lid (5C).
5. Reinstall the screws. Do not over-tighten the screws.
Replacement 9-volt alkaline batteries can be found at many retailers.  
Step
4
Step
5