Chauvet 648 Manuale Utente

Pagina di 21
 
 
 
 
Page 18 of 21 
Impulse™ 648 User Manual Rev. 6 
DMX Configuration 
 
The DMX fixture configuration consists in determining how many channels 
each fixture will need as well as assigning the corresponding DMX channels to 
each fixture in order to size correctly the DMX controller. 
 
 
 
Personalities 
 
A DMX personality describes what channel or channels control which fixture 
parameters. A DMX fixture may have many personalities to choose from. Each 
personality requires a different number of channels, based on the number of 
features the fixture enables. The number of DMX channels used by a fixture 
may vary from only one (usually the general dimmer control) to 15 or more. 
When a job does not require using all the fixture’s capabilities, the user can 
select a more basic personality (less channels), allowing the DMX controller to 
accommodate more DMX fixtures. 
 
 
 
Starting Address 
 
For the DMX controller to control each DMX fixture, the user must first 
configure each fixture’s personality to determine the number of channels 
required to control the fixture. Each channel will have a DMX address 
assigned to it.  
However, since assigning  a particular DMX address to each channel is 
impractical, the user will only need to configure the DMX address on each 
fixture that corresponds to the fixture’s first channel of control. This is the 
fixture’s starting address. The fixture will automatically assign the other 
channels to the subsequent DMX addresses.  
Once this assignment is complete, and based on the number of channels 
used, the fixture will respond to the DMX signals sent to the range of DMX 
channels that begins with the starting address. 
For example, a fixture that uses six DMX channels with a starting address of 
100, will accept DMX data sent by the DMX controller to channels 100, 101, 
102, 103, 104, and 105. 
 
 
 
 
 
 
Assigning Addresses 
 
The user must carefully assign the starting addresses for each individual 
fixture to avoid DMX channel overlapping. If the DMX channels do overlap, the 
impacted fixtures could operate erratically. 
However, the user may decide to configure two or more similar fixtures with 
the same personality and starting address. In this case, all the fixtures with the 
same starting address will operate in unison. 
 
 
 
 
 
 
   
 
DMX Connectivity 
 
Connecting the DMX fixtures to a DMX controller in small to medium 
installations is usually a rather simple operation that requires a minimum of 
tools and some planning (not including the actual fixture rigging and 
configuration).  
However, in large installations it may be necessary to plan carefully the 
position and cabling of each fixture to avoid unexpected problems. 
 
 
 
Fixture Location 
 
The order in which the fixtures connect to the DMX controller is not important 
and has no effect on how a controller communicates to each fixture. However, 
the user should always define a physical location for the fixtures that provides 
for the easiest and most direct cabling to the controller and other fixtures.