Chauvet 648 Manuale Utente

Pagina di 21
 
 
 
 
Page 20 of 21 
Impulse™ 648 User Manual Rev. 6 
(DMX Connectivity cont.) 
 
 
   
 
 
 
Test all DMX cables with an ohmmeter to verify their correct polarity and 
to make sure that there are no short-circuits between any of the pins, or 
between any pin and ground.  
If the common wire (shield) touched the chassis ground, a ground loop 
could form, which may cause the fixture to perform erratically. 
 
 
 
3-Pin to 5-Pin 
Conversion Chart 
 
If you use a DMX controller or fixture with a 5-pin DMX connector, you will 
need to use a 5-pin to 3-pin adapter. The chart below details a proper cable 
conversion. 
 
 
3-Pin to 5-Pin Conversion Chart 
 
 
Conductor 
3-Pin Female (Output) 
5-Pin Male (Input) 
 
 
Ground/Shield 
Pin 1 
Pin 1 
 
 
Negative (-) signal 
Pin 2 
Pin 2 
 
 
Positive (+) signal 
Pin 3 
Pin 3 
 
 
Not Used 
 
Pin 4 
 
 
Not Used 
 
Pin 5 
 
 
 
 
DMX Connection 
 
Make sure that the fixtures with which you are working can operate in DMX 
mode, not in a proprietary connection mode. Refer to the fixtures’ manual to 
learn how to enable their respective DMX modes. 
The procedure below illustrates a possible DMX connection method. 
 
 
 
   
1.  Connect the 3-pin, male connector of the first DMX cable to the DMX 
Output connector (3-pin, female) of the DMX controller. 
2.  Connect the 3-pin, female connector of the first DMX cable coming from 
the controller to the DMX Input connector (3-pin, male) of the first DMX 
fixture.  
3.  Connect the 3-pin, male connector of the second DMX cable to the DMX 
Output connector (3-pin, female) of the first DMX fixture. 
4.  Connect the 3-pin, female connector of the second DMX cable coming 
from the first DMX fixture to the DMX Input connector of the second DMX 
compatible fixture. 
5.  Continue linking the other DMX fixtures in the same way.