Setup
 
-6- 
 
OVATION™ E-190WW User Manual Rev. 3 
3. Setup 
AC Power 
Each OVATION™ E-190WW has an auto-ranging power supply that works with an input 
voltage range of 100~240 VAC, 50/60 Hz. To determine the power requirements for 
each OVATION™ E-190WW, refer to the label affixed to the product. You can also refer 
to th
 chart in this manual. 
The listed current rating indicates the maximum current draw during normal operation. 
For more information, you may download Sizing Circuit Breakers from the CHAUVET® 
website 
. 
 
Always connect this product to a protected circuit with an appropriate electrical 
ground to avoid the risk of electrocution or fire. 
 
Never connect this product to a rheostat (variable resistor) or dimmer circuit, even 
if the rheostat or dimmer channel serves only as a 0 to 100% switch. 
AC Plug 
The  OVATION™  E-190WW  comes with a power input cord terminated with a Neutrik® 
powerCON® A connector on one end and an Edison plug on the other end (U.S. market). 
If the power input cord that came with your product has no plug, or if you need to change 
the Edison plug, use the table below to wire the new plug to the power input cord. 
 
Connection 
Wire (U.S.) 
Wire (Europe) 
Screw Color 
AC Live 
Black 
Brown 
Yellow or Brass 
AC Neutral 
White 
Blue 
Silver 
AC Ground 
Green/Yellow 
Green/Yellow 
Green 
 
 
 
Fuse Replacement 
 
 
Make sure to disconnect the product’s power cord before replacing a blown fuse. 
 
1.  Disconnect this product from power. 
2.  Using a Phillips #2 head screwdriver, unscrew the fuse holder 
cap from the housing. 
3.  Remove the blown fuse and replace with another fuse of the 
same type and rating (T 3.15 A, 250 V). 
4.  Screw the fuse holder cap back in place and reconnect power. 
 
 
Always replace the blown fuse with another of the same type and rating.