Chauvet E-190WW Manuale Utente

Pagina di 21
 
Setup
 
OVATION™ E-190WW User Manual Rev. 3 
 
-7- 
Power Linking 
The OVATION™ E-190WW supports power linking. You can power link up to 4  units  on 
120 V; up to 7 units on 208 V; or up to 8 units on 230 V. 
This product comes with a Neutrik® powerCON® input power cord. This product does not 
come with a power linking cable; however, a power linking cable is available as an option. 
DMX Linking 
You can link the OVATION™  E-190WW  to a DMX controller using a standard DMX 
serial connection. If using other DMX-compatible products with the OVATION™  E-
190WW, you can control each individually with a single DMX controller. 
DMX Modes 
The  OVATION™ E-190WW uses the standard DMX data connection for the 1-, 2-  and 
3-channel DMX modes. 
·  Refer to the 
 chapter for a brief description of these modes. 
·  Refer to the 
 chapter to learn how to configure the OVATION™ E-190WW 
to work in these modes. 
·  The 
 section provides you with detailed information regarding the DMX 
modes. 
Master/Slave 
Connectivity 
The Master/Slave mode allows a single OVATION™ E-190WW (the “master”) to control 
the actions of one or more OVATION™ E-190WW units (the “slaves”) without the need 
of  a DMX controller  to control the slaves.  Once set and connected, the slaves  will 
operate in unison with the master.  For instructions on connecting and configuring this 
product, se
. 
 
DO NOT connect a DMX controller to products operating in Slave mode. The DMX 
controller signals may interfere with the signals from the master product. 
 
Th
  section  of this manual provides detailed instructions on how to 
configure the master and slaves. 
 
If you are not familiar with or need more information about DMX standards, 
master/slave connectivity, or the DMX cables needed to link this product to a DMX 
controller, download the DMX Primer
 
from the CHAUVET® website: 
.