Euphonix System 5 Installation Guide
System 5 Components
48
SH612 Studio Hub
Figure 3-17 SH612 Studio Hub
Video In (BNC): Connect this to house blackburst or composite sync.
AES Sync In (female XLR): Connect this port to a digital sync reference.
AES Sync Out Ports (four male XLR): This signal is active regardless of selected sync 
source. 
Word In (BNC): Connect this port to a digital sync reference.
Word Out (BNC): This signal is active regardless of selected sync source.
MADI In / Out Ports (24 BNC): Digital audio in and outs. See the MADI Hookup dia-
grams (Figure 2-9 and Figure 2-8) for details on these connections.
Control Port (DB-9): Connect to Serial Port 1 on PC253i Interface Computer.
Power Connectors (IEC): Accepts two standard IEC power cords (provided). Two autorang-
ing switching supplies accept voltages between 100–240 VAC, 50–60 Hz.
NOTE: The connections described above pertain only to a System 5 console config-
uration. The other connections on the SH612 are used when installed with the 
R-1 Digital Audio Multitrack Recorder. 