Hitachi SJ300-037HFE Manuale Utente

Pagina di 289
“A” Group: Standard Functions
Configur
ing Dr
iv
P
a
ra
meters
3–10
NOTE: The base frequency must be less than or equal to the maximum frequency (ensure that 
A003 
≤ A004).
A203 Base frequency setting, 
2nd motor
Settable from 30 Hz to the 
maximum frequency 
✘ ✘
50.
60.
60.
Hz
>A203 2F-BASE
F         0060Hz
A303 Base frequency setting, 
3rd motor
Settable from 30 Hz to the 
maximum frequency 
✘ ✘
50.
60.
60.
Hz
>A303 3F-BASE
F         0060Hz
A004 Maximum frequency 
setting
Settable from 30 Hz to
400 Hz
✘ ✘
50.
60.
60.
Hz
>A004 F-max
F         0060Hz
A204 Maximum frequency 
setting, 2nd motor
Settable from 30 Hz to
400 Hz
✘ ✘
50.
60.
60.
Hz
>A204 2F-max
F        0060Hz
A304 Maximum frequency 
setting, 3rd motor
Settable from 30 Hz to
400 Hz
✘ ✘
50.
60.
60.
Hz
>A304 3F-max
F        0060Hz
“A” Function
Run 
Mode
Edit
Lo Hi
Defaults
Units
SRW Display
Func.
Code
Name
Description
–FE
(CE)
–FU
(UL)
–FR
(Jpn)