troubleshooting Guide
This  section  provides  a  list  of  the  more  frequently  encountered  malfunctions,  their  causes  and  corrective  actions.  The  operator  or 
maintenance personnel can perform some corrective actions, and others may require the assistance of a qualified D
e
WALT technician or 
your dealer.
Problem 
Code
Excessive air tank pressure-safety valve pops off  ......................................................................1, 2
Air leaks  .................................................................................................................................... 3
Air leaks in air tank or at air tank welds .................................................................................... 4
Air leaks between head and valve plate .................................................................................... 5
Air leaks from safety valve......................................................................................................... 6
Knocking Noise .......................................................................................................................... 6
Pressure reading on the regulated pressure gauge drops when an accessory is used ........... 7
Compressor is not supplying enough air to operate accessories.............................................. 8, 9, 10, 11, 12
Regulator knob has continuous air leak .................................................................................... 13
Regulator will not shut off air outlet ........................................................................................... 13
Motor will not run ....................................................................................................................... 14, 15, 16, 17, 18, 19
troubleshooting Codes
CoDe
PoSSIBLe CAuSe
PoSSIBLe SoLutIon
1
Pressure switch does not shut off motor when compressor 
reaches cut-out pressure
Set the On/Off switch to OFF, if the unit does not shut 
off contact a D
e
WALT factory service center or a D
e
WALT 
authorized service center.
2
Pressure switch cut-out
 too high
Contact a D
e
WALT factory service center or a D
e
WALT 
authorized service center.
3
Tube fittings are not tight enough
Tighten fittings where air can be heard escaping. Check 
fittings with soapy water solution. 
Do not overtighten.