Toshiba EO1-33056D Manuale Utente

Pagina di 139
2. PRINTER SETUP 
ENGLISH VERSION EO1-33056 
2.8 Setting an Operating Environment
 
E2-42 
2.8.6  Real Time Clock Setting 
(Cont.) 
 
 
 
 
(3)  Low Battery Check Setting 
This parameter is to choose whether to activate the low battery check 
function or not.  
 
 
 
Press the 
[PAUSE] key to set.  
 
 
 
 
 
 
 
 
After selecting the low battery check, press the 
[PAUSE] key. 
 
(4)  RTC Data Renewal Timing Setting 
This parameter is to choose the RTC data renewal timing.  
 
 
 
Press the 
[PAUSE] key to set.  
 
 
 
 
 
 
 
 
 
 
 
 
 
After selecting the RTC data renewal timing, press the 
[PAUSE] key. 
The current date is displayed.  
 
 
 
 
Press the 
[FEED] and [RESTART] keys at the same time to return to the 
<8>RTC SET display.  
 
 
<8>RTC SET 
LOW BATT.     CHECK 
LOW BATT.     ON 
[RESTART]
[FEED]
Low battery check is 
activated.  
Low battery check is not 
activated.  
LOW BATT.     OFF 
<8>RTC SET 
RENEWAL 
RENEWAL     BATCH 
[RESTART]
[FEED]
Batch print is possible.  However, the same time is 
printed on the all media issued in a batch because 
the real time clock data is read only for the first 
media.
 
A real time can be printed on each media.  However, 
the printer needs to stop the motion before printing 
each media to read the real time clock data.
 
RENEWAL     PAGE 
NOTE: 
1.  Be sure to load the battery and set 
the low battery check function to 
ON whenever the real time clock 
is used.  If the battery is not 
loaded or the battery voltage is 
low, the real time clock data is 
erased at the power off time. 
2.  When the low battery check 
function is set to ON and if the 
battery voltage is 1.9V or less, the 
printer will result in a “LOW 
BATTERY” error and stop at the 
power on time.  As a restart is 
invalidated in this case, hold 
down the [RESTART] key to 
cause the printer to enter 
<1>RESET mode, access the Real
Time Clock setting mode, and set 
the low battery function to OFF. 
<8>RTC SET 
DATE     06/03/01 
<8>RTC SET