Panasonic 324566-A Manuale Utente

Pagina di 172
A List of indicators 
Nortel Secure Router 8012 
Hardware Description 
 
A-2 
Nortel Networks Inc. 
Issue 5.3 (6 April 2009) 
 
Name 
Silkscreen 
Description 
ALM (red) 
The fan warning LED. Constant ON means the fan is not 
in position or has failed. 
PRN (green) 
The LED of the first power module in position. Constant 
ON means the power module is in position. Constant 
OFF means the power module is not in position. 
PWR1 
ALM (red) 
The first power module failure LED. Constant ON 
means the power module disabled or has failed. 
PRN (green) 
The LED of the second power module in position. 
Constant ON means the power module is in position. 
Constant OFF means the power module is not in 
position . 
PWR2 
ALM (red) 
The second power module failure LED. Constant ON 
means the power module disabled or has failed. 
LINK 
(green) 
OFF means the link is not connected and ON means the 
link is connected. 
10/100/1000M 
Ethernet 0 
ACT 
(yellow) 
OFF means no data is being transmitted on the interface 
and blinking means data is being transmitted or received.
LINK 
(green) 
OFF means the link is not connected and ON means the 
link is connected. 
100/1000M 
Ethernet 1
 
ACT 
(yellow) 
OFF means no data is being transmitted on the interface 
and blinking means data is being transmitted or received.
LINK 
(green) 
OFF means the link is not connected and ON means the 
link is connected. 
100/1000M 
Ethernet 2
 
ACT 
(yellow) 
OFF means no data is being transmitted on the interface 
and blinking means data is being transmitted or received.
 
A.1.2 NPU indicators 
Table A-2 shows the status and description of NPU indicators. 
Table A-2 Description of NPU indicators
 
Name 
Description 
RUN (Green)
 
The running LED. Blinking means the NPU works normally. 
Constant OFF means the NPU is not in position or it failed. 
ALM (Red)
 
The alarm LED. Constant ON means the NPU failed.