I-162
4.3.2 I/O DEVICE PARAM
Parameters for up to five types of input/output devices can be set in DEV <0> to <4>.
[I/O DEVICE PARAM]
DEV 0
PARAM
2.2/7
#
#
#
9101 DEVICE NAME
-
9111 DC2/DC4 OUTPUT
-
9121 EIA CODE
[
-
9102 BAUD RATE
-
9112 CR OUTPUT
-
9122
]
-
9103 STOP BIT
-
9113 EIA OUTPUT
-
9123
#
-
9104 PARITY CHECK
-
9114 FEED CHR.
-
9124
∗ -
9105 EVEN PARITY
-
9115 PARITY V
-
9125
=
-
9106 CHR. LENGTH
-
9116 TIME-OUT(sec)
-
9126
:
-
9107 TERMINATOR TYPE
-
9117 DR OFF
-
9127
$
-
9108 HAND SHAKE
-
9118 DATA ASCII
-
9128
!
-
9109 DC CODE PARITY
-
9119 INPUT TYPE
-
9129
9110
9120
9130
# ( ) DATA ( )
WORK PROCESS
I/O PAR
SETUP MENU
# Item
Contents
Setup
range
(unit)
9101 DEVICE NAME
Set the device name corresponding to the device
No.
Set a simple name for quick identification.
No.
Set a simple name for quick identification.
Use alphabet
characters‚ numerals
and symbols to set a
name within 3
characters.
characters‚ numerals
and symbols to set a
name within 3
characters.
9102 BAUD RATE
Set the serial communication speed.
0: 19200 (bps)
1: 9600
2: 4800
2: 4800
3: 2400
4: 1200
5: 600
5: 600
6: 300
7: 150
9103 STOP BIT
Set the stop bit length used in the start-stop system. 1: 1 (bit)
2: 1.5
3: 2
3: 2
9104 PARITY CHECK
Specify whether to add the parity check bit to the
data during communication.
data during communication.
0:
Parity bit not
added
added
1: Parity bit added
9105 EVEN PARITY
Specify the odd or even parity when it is added to
the data.
the data.
0: Odd parity
1: Even parity
1: Even parity
9106 CHR. LENGTH
Set the length of the data bit.
0: 5 (bit)
1: 6
2: 7
3: 8
1: 6
2: 7
3: 8
9107 TERMINATOR TYPE
The code to terminate data reading can be selected. 0 and 3: EOR
1 and 2: EOB or
EOR
EOR