4.  Parameters (User) 
4.3  I/O Parameters 
 
 
 
I-162 
4.3.2  I/O DEVICE PARAM 
 
Parameters for up to five types of input/output devices can be set in DEV <0> to <4>. 
 
 
  [I/O DEVICE PARAM] 
DEV 0 
PARAM 
2.2/7 
 
  # 
 
  9101  DEVICE NAME 
9111  DC2/DC4 OUTPUT 
9121  EIA CODE 
  9102  BAUD RATE 
9112  CR OUTPUT 
 
9122   
  9103  STOP BIT 
9113  EIA OUTPUT 
 
9123 
  9104  PARITY CHECK 
9114  FEED CHR. 
 
9124 
∗ - 
  9105  EVEN PARITY 
9115  PARITY V 
 
9125 
  9106  CHR. LENGTH 
9116  TIME-OUT(sec)   
9126 
  9107  TERMINATOR TYPE 
9117  DR OFF 
 
9127 
  9108  HAND SHAKE 
9118  DATA ASCII 
 
9128 
  9109  DC CODE PARITY 
9119  INPUT TYPE 
 
9129 
 
  9110   
 
9120   
 
 
9130 
 
 
    # (            ) DATA (            ) 
 
WORK PROCESS 
I/O PAR 
SETUP MENU 
 
 
 
# Item 
Contents 
Setup 
range 
(unit)
9101  DEVICE NAME 
Set the device name corresponding to the device 
No. 
Set a simple name for quick identification. 
Use alphabet 
characters‚ numerals 
and symbols to set a 
name within 3 
characters. 
9102  BAUD RATE 
Set the serial communication speed. 
0: 19200  (bps) 
1:   9600   
2: 4800 
3: 2400 
4: 1200 
5: 600 
6: 300 
7: 150 
9103  STOP BIT 
Set the stop bit length used in the start-stop system. 1:  1  (bit) 
2:  1.5 
3:  2 
9104  PARITY CHECK 
Specify whether to add the parity check bit to the 
data during communication. 
0: 
Parity bit not 
added 
1:  Parity bit added 
9105  EVEN PARITY 
Specify the odd or even parity when it is added to 
the data. 
0: Odd parity 
1: Even parity 
9106  CHR. LENGTH 
Set the length of the data bit. 
0:  5  (bit) 
1:  6 
2:  7 
3:  8 
9107  TERMINATOR TYPE
The code to terminate data reading can be selected. 0 and 3: EOR 
1 and 2: EOB or 
EOR