Maxtor STM3200820A Manuale Utente

Pagina di 50
18
DiamondMax 21 PATA Product Manual, Rev. B
2.10
Acoustics
Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All mea-
surements are consistent with ISO document 7779. Sound power measurements are taken under essentially 
free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing upward.
Note. For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is defined 
by the following equation: 
 
 
(Number of seeks per second = 0.4 / (average latency + average access time)
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and 
power to operational levels.
Table 5: 
Fluid Dynamic Bearing (FDB) motor acoustics
Acoustic mode
Idle*
Quiet seek
STM3320820A
2.7 Bels (typ)
 
3.0 Bels (max)
3.0 Bels (typ)
 
3.4 Bels (max)
STM3300620A
 
STM3250620A
 
STM3250820A
 
STM3200820A
2.5 Bels (typ)
 
2.8 Bels (max)
3.0 Bels (typ)
 
3.1 Bels (max)
STM3160215A
 
STM380215A
2.8 Bels (typ)
 
3.0 Bels (max)
3.0 Bels (typ)
 
3.2 Bels (max)