153
Viewing Trip Information
In the event that the condition causing an Alarm does not return to the normal operating level within a 
specified time a Trip is incurred.
When a trip occurs, the resultant error information may be viewed either from the 
 screen 
(Program 
⇒ System Information and Setup ⇒
 Trip History) or from the Monitor screen.
Trip History
The Trip History screen records the system parameters for up to 24 trips (RTC option required). The 
recorded trips are numbered from zero to 23. Once the Trip History record reaches trip number 23, the 
oldest recorded trip will be deleted with each new record stored (first-in first-out). The Trip # field may be 
selected and scrolled through to view the recorded trip information for a given trip number. The monitored 
parameters are listed in 
 as At-trip Recorded Parameters (parameter readings at the time that 
the trip occurred).
Table 14. Trip History Record Parameters (RTC option required).
Trip Record at Monitor Screen
The Monitor screen records and displays the trip name of up to four trips and catalogs each trip as Past 
Trip #1
Past Trip #2Past Trip #3, and Past Trip #4. Once reset (Clear Trip), the trip records are 
erased. If no trips have occurred since the last reset, No Error is displayed for each trip record.
Note:
An improper ASD setup may cause some trips — reset the ASD to the factory default 
settings before pursuing a systemic malfunction (Program 
 Utilities  Type Resets 
 Restore Factory Defaults).
The at-trip frequency of the last incurred trip may be viewed at the Monitor screen (see 
). The 
Monitor screen at-trip record is erased when the ASD is reset and may be viewed without the use of the 
RTC option. The current output frequency is displayed here when no trip is active.
Clearing a Trip
Once the cause of the trip has been corrected, performing a 
 re-enables the ASD for normal 
operation (clears the fault screen).
The fault screen may also be cleared using either of the following methods:
• Cycling power (trip info may be saved via 
parameter 
if desired),
• Pressing the Stop|Reset key twice,
• Remotely via the communications channel,
• Momentarily connecting terminal RES to CC of the Control Terminal Strip, or
• Via Program 
⇒ Utilities ⇒ Type Resets ⇒ Clear Psast Trips.
At-trip Recorded Parameters
1) Trip Number
9) Bus Voltage
17) Torque Reference
25) ASD Load
2) Trip Type
10) Discrete Input Status
18) Torque Current
26) DBR Load
3) Time and Date
11) OUT1/OUT2/FL Status
19) Excitation Current
27) Input Power
4) Frequency at Trip
12) Timer
20) PID Value
28) Output Power
5) Output Current
13) Post Compensation Frequency
21) Motor Overload
29) Peak Current
6) Output Voltage
14) Feedback (inst.)
22) ASD Overload
30) Peak Voltage
7) Direction
15) Feedback (1 sec.)
23) DBR Overload
31) PG Speed
8) Frequency Reference
16) Torque
24) Motor Load
32) PG Position