Hardware Preparation and Installation
2-2
MVME162 Embedded Controller Installation Guide
2
MVME162 operates with its required and factory-installed Debug Monitor, 
MVME162Bug (162Bug), with these factory jumper settings. Manually 
configurable items include: 
SIM selection for serial port B configuration (J10)
System controller selection (J1) 
Synchronous clock selection (J11) for Serial Port 1/Console 
Synchronous clock selection (J12) for Serial Port 2 
SRAM backup power source selection (J20) 
EPROM size selection (J21) 
General-purpose readable register configuration (J22) 
SIM Selection
Port B of the MVME162’s Z85230 serial communications controller is 
configurable via a serial interface module (SIM) which is installed at connector 
J10 on the MVME162 board. Four serial interface modules are available:
EIA-232-D (DCE and DTE)
EIA-530 (DCE and DTE)
You can change Port B from an EIA-232-D to an EIA-530 interface (or vice-
versa) by mounting the appropriate serial interface module. Port B is routed 
(via the SIM at J10) to the 25-pin DB25 front panel connector marked 
SERIAL 
PORT 2
.
For the location of SIM connector J10 on the MVME162, refer to Figure 2-1.   
Figure 2-2 illustrates the secondary side (bottom) of a serial interface module, 
showing the J1 connector which plugs into SIM connector J10 on the 
MVME162. Figure 2-3 (sheets 3-6) and Figure 2-4 illustrate the six 
configurations available for Port B.
For the part numbers of the serial interface modules, refer to Table 2-1. The 
part numbers are ordinarily printed on the primary side (top) of the SIMs, but 
may be found on the secondary side in some versions.
If you need to replace an existing serial interface module with a SIM of another 
type, go to Removal of Existing SIM below. If there is no SIM on the main board, 