The following sections discuss the installation of IndustryPacks (IPs) on the 
MVME162, the installation of the MVME162 into a VME chassis, and the 
system considerations relevant to the installation. Before installing 
IndustryPacks, ensure that the serial ports and all header jumpers are 
configured as desired.
IP Installation on the MVME162
Up to four IndustryPack (IP) modules may be installed on the MVME162. 
Install the IPs on the MVME162 as follows:
1.
Each IP has two 50-pin connectors that plug into two corresponding 50-
pin connectors on the MVME162: J2/J3, J7/J8, J13/J14, J18/J19. See Figure 
2-1 for the MVME162 connector locations.
Orient the IP(s) so that the tapered connector shells mate properly. 
Plug IP_a into connectors J2 and J3; plug IP_b into J7 and J8. Plug IP_c 
into J13 and J14; plug IP_d into J18 and J19. If a double-sized IP is used, 
plug IP_ab into J2, J3, J7, and J8; plug IP_cd into J13, J14, J18, and J19.
2.
Four additional 50-pin connectors (J6, J5, J17, and J16) are provided behind 
the MVME162 front panel for external cabling connections to the IP 
modules. There is a one-to-one correspondence between the signals on the 
cabling connectors and the signals on the associated IP connectors (i.e., J6 
has the same IP_a signals as J2; J5 has the same IP_b signals as J7; J17 has 
the same IP_c signals as J13; and J16 has the same IP_d signals as J18.
Connect user-supplied 50-pin cables to J6, J5, J17, and J16 as needed. 
Because of the varying requirements for each different kind of IP, 
Motorola does not supply these cables.
Bring the IP cables out the narrow slots in the MVME162 front panel 
and attach them to the appropriate external equipment, depending on 
the nature of the particular IP(s).