Motorola MVME162 Manuale Utente

Pagina di 136
Hardware Preparation and Installation
2-10
MVME162 Embedded Controller Installation Guide
2
MVME162 Module Installation
With EPROM, IndustryPack, and SIMs installed and headers properly 
configured, proceed as follows to install the MVME162 in the VME chassis:
1.
Turn all equipment power OFF and disconnect the power cable from the 
AC power source.
C
aution
 
Inserting or removing modules while power is applied
could result in damage to module components.
!
WARNING
Dangerous voltages, capable of causing death, are present in
this equipment. Use extreme caution when handling, test-
ing, and adjusting.
2.
Remove the chassis cover as instructed in the user’s manual for the 
equipment.
3.
Remove the filler panel from the card slot where you are going to install 
the MVME162.
If you intend to use the MVME162 as system controller, it must occupy 
the leftmost card slot (slot 1). The system controller must be in slot 1 
to correctly initiate the bus-grant daisy-chain and to ensure proper 
operation of the IACK daisy-chain driver.
If you do not intend to use the MVME162 as system controller, it can 
occupy any unused double-height card slot.
4.
Slide the MVME162 into the selected card slot. Be sure the module is 
seated properly in the P1 and P2 connectors on the backplane. Do not 
damage or bend connector pins.
5.
Secure the MVME162 in the chassis with the screws provided, making 
good contact with the transverse mounting rails to minimize RF 
emissions.
6.
Install the MVME712 series transition module in the front or the rear of the 
VME chassis. (To install an MVME712M, which has a double-wide front 
panel, you may need to shift other modules in the chassis.)
7.
On the chassis backplane, remove the 
INTERRUPT ACKNOWLEDGE
 
(IACK) and 
BUS GRANT
 (BG) jumpers from the header for the card slot 
occupied by the MVME162.