CHAPTER  8   WATCH  TIMER 
 
162 
User’s Manual  U15331EJ4V1UD
 
(1) Watch timer 
An interrupt request (INTWT) occurs at an interval of 0.5 second when using either the 4.19 MHz main 
system clock or the 32.768 kHz subsystem clock. 
Also, an interrupt request (INTWT) occurs at an interval of 1.0 seconds when using the 32.768 kHz 
subsystem clock via a setting in the watch timer interrupt time selection register (WTIM). 
 
Caution  An interval of 0.5 second cannot be created when using the 5.0 MHz main system clock.  
Instead, switch to the 32.768 kHz subsystem clock, and then create the 0.5-second interval. 
 
(2) Interval timer 
An interrupt request (INTWTI) occurs at preset intervals. 
 
Table 8-1.  Interval Time of Interval Timer 
Interval Time 
At f
X
 = 5.0 MHz 
At f
X
 = 4.19 MHz 
At f
XT
 = 32.768 kHz 
At f
XT
/2 = 16.384 kHz 
2
4
×1/f
W
 
409.6 
µ
s 488 
µ
s 488 
µ
s 976 
µ
2
5
×1/f
W
 
819.2 
µ
s 977 
µ
s 977 
µ
s 1.95 
ms 
2
6
×1/f
W
 
1.64 ms 
1.95 ms 
1.95 ms 
3.90 ms 
2
7
×1/f
W
 
3.28 ms 
3.91 ms 
3.91 ms 
7.82 ms 
2
8
×1/f
W
 
6.55 ms 
7.81 ms 
7.81 ms 
15.6 ms 
2
9
×1/f
W
 
13.1 ms 
15.6 ms 
15.6 ms 
31.2 ms 
Remarks 1.  f
W
:  Watch timer clock frequency (f
X
/2
7
, f
XT
, or f
XT
/2) 
 
2.  f
X
:  Main system clock oscillation frequency  
 
3.  f
XT
:  Subsystem clock oscillation frequency  
 
8.2  Configuration of Watch Timer 
The watch timer includes the following hardware. 
 
Table 8-2.  Configuration of Watch Timer 
Item Configuration 
Counter 5 
bits 
× 1 
Prescaler 9 
bits 
× 1 
Control registers 
Watch timer mode control register (WTM) 
Watch timer interrupt time selection register (WTIM)