11.3  Serial Interface 20 Control Registers 
Serial interface 20 is controlled by the following six registers. 
•  Serial operation mode register 20 (CSIM20) 
•  Asynchronous serial interface mode register 20 (ASIM20) 
•  Asynchronous serial interface status register 20 (ASIS20) 
•  Baud rate generator control register 20 (BRGC20) 
•  Port mode register 2 (PM2) 
• Port 2 
 
(1)  Serial operation mode register 20 (CSIM20) 
CSIM20 is used to make the settings related to 3-wire serial I/O mode.  
CSIM20 is set with a 1-bit or 8-bit memory manipulation instruction. 
RESET input sets CSIM20 to 00H. 
 
Figure 11-3.  Format of Serial Operation Mode Register 20 
CSIE20
0
1
3-wire serial I/O mode operation control
CSIE20
0
0
0
0
DIR20 CSCK20
0
CSIM20
Symbol
Address
After reset
R/W
FF72H
00H
R/W
<7>
6
5
4
3
2
1
0
Operation disabled
Operation enabled
DIR20
0
1
First-bit specification
MSB
LSB
CSCK20
0
1
3-wire serial I/O mode clock selection
External clock input to the SCK20 pin
Output of the dedicated baud rate generator
 
 
Cautions  1.  Bits 0 and 3 to 6 must be set to 0. 
 
2.  CSIM20 must be cleared to 00H if UART mode is selected. 
 
3.  When the external input clock is selected in 3-wire serial I/O mode, set input mode by 
setting bit 0 of port mode register 2 (PM2) to 1. 
 