NEC PD78F9488 Manuale Utente

Pagina di 388
CHAPTER  15   REMOTE  CONTROLLER  RECEIVER  (
µ
PD789489, 78F9489 ONLY) 
User’s Manual  U15331EJ4V1UD 
277
15.3  Registers to Control Remote Controller Receiver 
The remote controller receiver is controlled by the following register. 
 
•  Remote controller receive control register (RMCN) 
 
(1)  Remote controller receive control register (RMCN) 
This register is used to enable/disable remote controller reception and to set the noise elimination width, clock 
internal division, input invert signal, and source clock. 
RMCN is set with a 1-bit or 8-bit memory manipulation instruction. 
RESET input sets RMCN to 00H. 
 
Figure 15-3.  Format of Remote Controller Receive Control Register (1/2) 
Symbol 
7 6 5 4 3 2 1 0 
Address 
After 
reset 
R/W 
RMCN RMEN  NCW  PRSEN  RMIN 
RMCK1 RMCK0 FF60H  00H 
R/W 
 
 
RMEN 
Control of remote controller receive operation 
 
Disable remote controller reception 
 
Enable remote controller reception 
 
 
NCW 
Noise elimination width control signal 
 
Eliminate noise less than 1/f
PRS
 
 
Eliminate noise less than 2/f
PRS
 
 
 
PRSEN 
Internal clock division control signal 
 
Clock not divided internally (f
PRS
 = f
REM
 
Clock internally divided into two (f
PRS
 = f
REM
/2) 
 
 
RMIN 
Remote controller input invert signal 
 
Input positive phase 
 
Input negative phase 
 
Cautions  1.  Always set bits 2 and 3 to 0. 
 
2.  To change the values of NCW, PRSEN, RMIN, RMCK1, and RMCK0, disable remote 
controller reception (RMEN = 0) first. 
 
Remarks  1.  f
REM
: Source clock of remote controller counter (selected by bits 0 and 1 (RMCK0 and RMCK1) 
 
2.  f
PRS
: Operation clock inside remote controller receiver