CHAPTER  17   STANDBY  FUNCTION 
312 
User’s Manual  U15331EJ4V1UD
 
17.2.2  STOP mode  
 
(1)  Setting and operation status of STOP mode  
The STOP mode is set by executing the STOP instruction. 
Caution  Because the standby mode can be released by an interrupt request signal, the standby 
mode is released as soon as it is set if there is an interrupt source whose interrupt request 
flag is set and interrupt mask flag is reset.  When the STOP mode is set, therefore, the 
HALT mode is set immediately after the STOP instruction has been executed, the wait time 
set by the oscillation stabilization time selection register (OSTS) elapses, and then the 
operation mode is set. 
The operation statuses in the STOP mode are shown in the following table. 
Table 17-3.  Operation Statuses in STOP Mode 
STOP Mode Operation Status During Main System Clock Operation 
Item 
Subsystem Clock Operating 
Subsystem Clock Stopped 
Main system clock 
Oscillation stopped 
Subsystem clock 
×4 
multiplication circuit 
Operation stopped 
CPU Operation 
stopped 
Ports (output latches) 
Status before STOP mode setting retained 
16-bit timer 20 
Operation stopped 
8-bit timer 50 
Operable
Note 1
 Operable
Note 2
 
8-bit timer 60 
Operable
Note 3
 
8-bit timer 61 
Operable
Note 3
 
Watch timer 
Operable
Note 4
 Operation 
stopped 
Watchdog timer 
Operation stopped 
Key return circuit 
Operable 
Serial interface 20 
Operable
Note 5
 
Serial interface 1A0 
Operable
Note 5
 
LCD controller/driver 
Operable
Note 4
 Operation 
stopped 
A/D converter 
Operation stopped 
Multiplier Operation 
stopped 
Remote controller 
receiver
Note 6
 
Operable
Note 4
 Operation 
stopped 
External interrupts 
Operable
Note 7
 
Notes 1.  Operation is enabled when either the subsystem clock or the input signal from the timer 60 (when timer 
60 is operable) is selected as the count clock. 
 
2.   Operation is enabled when the input signal from timer 60 (when timer 60 is operable) is selected as the 
count clock. 
 
3.   Operation is enabled when the external input clock is selected as the count clock. 
 
4.   Operation is enabled when the subsystem clock is selected. 
 
5.   Operation is enabled only for a maskable interrupt that is not masked. 
 
6.  
µ
PD789489 and 78F9489 only 
 
7.   Operation is enabled only for a maskable interrupt that is not masked.